text.skipToContent text.skipToNavigation

Digital Enhanced Plug Load Controller, On/Off, 120V, 60Hz

LMPL-201 Wattstopper
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getAggregateRating, 53ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

LMPL-201 Plug Load Controllers include a 20 amp relay for on/ off control of connected outlets, and a high-efficiency switching power supply. They are part of a Wattstopper Digital Lighting Management (DLM) system, and enable energy-efficient control of plug loads.
  • Send
  • Save as PDF
  • Add to favorites Remove from favorites

Features

  • Plenum-rated controller with line voltage relay and switching power supply
  • Component of Digital Lighting Management integrated control systems
  • Plugs to other components using Cat 5e cable and RJ45 connectors eliminating wiring errors
  • Plug n’ Go automatic configuration and Push n’ Learn for personalization
  • Integral current monitoring of total connected load
  • Accepts occupancy sensor signal for energy saving control of plug loads

Specifications

General Info
Product Line Wattstopper
UPC Number 754182928842
Country Of Origin China
Dimensions
Product Width US 6.0 in
Product Weight US 1.9 lb
Product Volume US 226.15 cu in
Product Depth US 4.41 in
Product Height US 7.4 in
Additional Information
RoHS Conformant Yes This product meets the material restrictions of Article 4 of the RoHS Directive (2011/65/EU), including Commission Delegated Directive 2015/863.
DesignLights Consortium Qualified System Yes
Security   Yes This product is ioXt certified

Reviews

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Questions & Answers

How to reset LLMR 213 WATTSTOPPER.?

Asked by: Ken teal
To reset an LMRC-213, you press and hold the CONFIG button for 5 seconds. You will see the red LED begin to flash rapidly. Press and hold the same CONFIG button for another 20 seconds. When the LED again begins to flash the LMRC is reset. * Please note that this will affect other DLM devices attached to the LMRC as well. For further assistance please call Wattstopper Technical Support @ 800-879-8585.
Answered by: Tier 1 Tech Support
Date published: 2022-04-04

Is there a wired (rj45) temperature sensor for wattstopper operation (instead of occupancy sensor)? Project: outdoor temperature sensing, to control hardwired on/off plug power (to heat mats for snow melt).

Asked by: schi
Unfortunately no, Wattstopper does not offer a temperature controlled sensor device.
Answered by: Tier 1 Tech Support
Date published: 2022-02-01
  • y_2024, m_3, d_27, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.38
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_en_US, sid_LMPL-201, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_legrand
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 8ms
  • QUESTIONS, PRODUCT