Emergency Lighting Control Unit for KO Mounting, USA
ELCU-200-U
Wattstopper
Bazaarvoice SAP Hybris Integration Version 2.8.1
Wattstopper's ELCU-200 Emergency Lighting Control Unit is a self-contained device that allows any standard lighting control device to control emergency lighting in conjunction with normal lighting in any area within a building.
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Features
- Eliminates energy waste caused by emergency lighting that is always on
- Integral push-to-test button activates emergency mode for a true test condition
- Connects to EMTS-100 Remote Test Switch or other input to activate emergency on from a remote location
- Operates as a control device or as a shunt
- Senses local single circuit power failure
- Zero cross switching technology for reliability and increased product life
- Compatible with Wattstopper occupancy sensors, daylighting controls, lighting control panels, and dimmers
Specifications
General Info
| Color | Red, White | ||
| Product Series | ELCU | ||
| Type | Emergency Load Controller | ||
| Material | ABS | ||
| Application Sector | Commercial | ||
| Product Line | Wattstopper | ||
| Country Of Origin | United States | ||
| Features | Push-to-Test on Device | ||
| Installation Location | Above Ceiling | ||
| Warranty Type | 5-Year | ||
| UPC Number | 754182928132 |
Dimensions
| Product Depth US | 1.9 in | ||
| Product Height US | 3.0 in | ||
| Product Volume US | 26.1 cu in | ||
| Product Width US | 2.2 in | ||
| Product Weight US | 0.3 lb |
Trade Programs
| BAA | Yes |
Additional Information
| DesignLights Consortium Qualified System | Yes | ||
| Security | Yes | This product is ioXt certified | |
| RoHS Compliant | Yes | This product meets the material restrictions of Article 4 of the RoHS Directive (2011/65/EU), including Commission Delegated Directive 2015/863. |
Technical Information
| Wire Connection Type | Flying Leads | ||
| Compatibility | EMTS-100 | ||
| Contact Configuration | N-C | ||
| Contact Rating | 24 VDC | ||
| Indoor/Outdoor | Indoor | ||
| Input Voltage | 120 to 277 VAC | ||
| Line Frequency | 50 Hz, 60 Hz | ||
| Load Rating | 10 A @ 120 VAC, 20 A @ 277 VAC | ||
| Location Rating | Dry | ||
| Mounting Type | 1/2 in Knockout | ||
| Number of Relays | 0 | ||
| Operating Temperature | 32°-131°F | ||
| Operating Temperature Max | 131 °F | ||
| Operating Temperature Min | 32 °F | ||
| Operating Humidity | 5-95% RH (Non-Condensing) | ||
| Storage Temperature | 23° - 176° F |
Resources
Installation Instructions
CAD Drawings
Specifications
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
Will this work with 120 volt emergency and 277 volt normal power
Yes, it will work, the normal power and emergency powers are completely isolated.
Date published: 2025-10-28
Installed ELCU to interface with the fire alarm system. cut the Test Loop wire andbconnected to the other ELCUs on the entire floor. After fixing the polarity of the run I installed the final ELCU, now all Emergency lights turned on and there is clicking?
Please reach out to our tech. support team for further assistance troubleshooting this issue.
Legrand Technical Support:
Phone: 1 800-879-8585, Option 3 then Option 1
Mon - Fri: 7am - 7pm CST (excluding holidays)
Date published: 2023-03-27
Is this compatible with 277 volt emergency and 120 volt normal power, fixture drivers are multi-volt.
Hi Jimmy,
Yes, it is, please follow the wiring diagram and keep the different voltage neutral wires isolated.
Date published: 2022-12-16
Can i use the ELCU to control/dim a LED fixture with integral emergency battery?
Good morning
The ELCU does not have dimming capability so if you are trying to dim LED fixtures I would recommmend that you use a control modular like and LMRC 211 which is 0 to 10 volt dimming with the ELCU.
Date published: 2022-09-15
Re: ELCU-200-347 Are the contacts rated for 20 amps , the spec sheet indicates 16a @120-347VAC Max Load Requirements . Please Clarify Thanks
The ELCU-200-347 is rated for 16amps @120-347vac
Date published: 2022-11-25
Good afternoon, can you control different lights in different rooms with one unit? Or do you have to install one device per room.
You could if you run the lights in parallel but when you are trying to control certain lights in one area other lights may come on that you may not want to use at that moment in another area. I would recommend one per a room.
Date published: 2022-06-21
Is the EL-CU-200 rated to switch LED drivers?
Yes, it can switch up to 20A of LED fixtures.
But I would de-rate your load to much less because of the LED inrush and other issues. A 10A LED load is huge these days.
Date published: 2021-02-05