Dual Tech Occupancy Sensor, 24VDC, Center Mount, 360°, USA
DT-300-U
Wattstopper
Bazaarvoice SAP Hybris Integration Version 2.8.1
The DT-300 Series Dual Technology Ceiling Sensors combine the benefits of passive infrared (PIR) and ultrasonic technologies to detect occupancy. Sensors have a flat, unobtrusive appearance and provide 360 degrees of coverage.
Contact Rating
1 A @ 30 VDC/VAC
- 1 A @ 30 VDC/VAC
- No Isolated Relay
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Features
Specifications
General Info
Product Line | Wattstopper | ||
UPC Number | 754182926800 | ||
Country Of Origin | United States | ||
Features | Motion Sensor, IR (Infrared), Indicator Lights | ||
Application Sector | Commercial | ||
Warranty Type | 5-Year |
Additional Information
Product Environmental Profile | Yes |
Technical Information
Sensor Type | Occupancy | ||
Amperage | 43 A | ||
Indicator | LED Light | ||
Sensing Range | 360 degrees, 1000 sq. ft. | ||
Voltage | 24 V, 24 V | ||
Connection Type | Wired |
Resources
CAD Drawings
57-003-4 - 8-Wire Occupancy Sensor with Manual-On Feature
dwg
57-003-4 - 8-Wire Occupancy Sensor with Manual-On Feature
png
57-003-4 - 8-Wire Occupancy Sensor with Manual-On Feature
dxf
57-010 - Multiple Occupancy Sensors Using One Power Pack
dxf
57-010 - Multiple Occupancy Sensors Using One Power Pack
png
57-010 - Multiple Occupancy Sensors Using One Power Pack
dwg
57-010 - Multiple Occupancy Sensors Using One Power Pack
pdf
57-039-8 - CI,DT,UT-355 Sensor Mounting Details
png
57-039-8 - CI,DT,UT-355 Sensor Mounting Details
dxf
57-039-8 - CI,DT,UT-355 Sensor Mounting Details
dwg
57-039-8 - CI,DT,UT-355 Sensor Mounting Details
pdf
57-303 - CI, DT, UT-305 Standard Schematic
png
57-303 - CI, DT, UT-305 Standard Schematic
pdf
57-303 - CI, DT, UT-305 Standard Schematic
dxf
57-303 - CI, DT, UT-305 Standard Schematic
dwg
60-601-2 - LI/LP Relay Panels Occupancy Sensor Connection
pdf
60-601-2 - LI/LP Relay Panels Occupancy Sensor Connection
dxf
60-601-2 - LI/LP Relay Panels Occupancy Sensor Connection
png
60-601-2 - LI/LP Relay Panels Occupancy Sensor Connection
dwg
DT-300
png
DT-300
dxf
DT-300
dwg
DT-300cp - DT-300 Coverage Pattern
png
DT-300cp - DT-300 Coverage Pattern
dxf
DT-300cp - DT-300 Coverage Pattern
dwg
DT-305
dwg
DT-305
png
DT-305
dxf
DT-305cp - DT-305 Coverage Pattern
dwg
DT-305cp - DT-305 Coverage Pattern
dxf
DT-305cp - DT-305 Coverage Pattern
png
View More
Product Environmental Profile
Specifications
Installation Instructions
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
Does the sensor provide data as to how often the area is occupied?
Hi Eric,
Sorry but no the sensor does not provide that data with this model.
Date published: 2023-01-10
Can the DT-300 sensor be wired to have sensor turns lights on and 0-10V dimmer switch controls light output?
Hello Mark,
The configuration you have requested is possible if the Sensor is wired to the 0-10v dimmer first, followed by the dimmer being wired to the light fixture driver.
*A potential delay can occur with the lighting fixture turning on/off via this configuration.
Please feel free to give us a call if you need further assistance.
legrand Contact information:
Phone #: 844-957-3783 - Option 1, followed by option 2 for Technical Support.
Monday - Friday | 8:00am - 6:00pm Eastern Standard Time (excluding holidays)
Best Regards,
Technical Support
Date published: 2022-05-23
Bazaarvoice SAP Hybris Integration Version 2.8.1