Wiremold OFR Series Overfloor Raceway Base and Cover
OFRBC-8
Wiremold
Bazaarvoice SAP Hybris Integration Version 2.8.1
Wiremold OFR Series Overfloor Raceway System provides four-channels of capacity and access to a wide range of power, communications, and A/V connectivity options in the smallest, lowest, narrowest, ADA compliant profile available in overfloor raceway systems. This system installs over existing floor coverings and is both tamper-resistant and installer-friendly, making it an ideal solution for relocatable or permanent installations where access through floors and ceilings is not an option.
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Specifications
General Info
Color | Black | ||
Type | Raceway | ||
Application Sector | Commercial | ||
Product Line | Wiremold | ||
Country Of Origin | United States | ||
Standard | cETLus Listed Surface Metal Raceway: Report Number G100217061CRT-001 | ||
UPC Number | 786776175141 |
Dimensions
Product Depth US | 0.63 in | ||
Product Height US | 6.88 in | ||
Product Volume US | 416.1 cu in | ||
Product Width US | 96.0 in | ||
Product Weight US | 15.11 lb |
Listing Agencies / 3rd Party Agencies
ETL Listed | Yes | ||
ETL ListingNumber | G100057860CRT-001 |
Buy American Act Compliance
NAFTA | Yes |
Additional Information
Product Environmental Profile | Yes | ||
RoHS Compliant | Yes | This product meets the material restrictions of Article 4 of the RoHS Directive (2011/65/EU), including Commission Delegated Directive 2015/863. |
Technical Information
Voltage | 300.0 V |
Resources
Cutsheet
Instruction Sheet
Product Environmental Profile
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
Can the OFR48-2 receive an underground conduit into the back of it. I know we would have to punch a hole into it and us a conduit fitting.
Hello,
Since the OFR base does not have knockouts it cannot be field modified.
OFRPT3 and OFRPT4 can be used to feed conduit from the floor below.
Thank you
Date published: 2023-10-03
Does the OFR system meet the intent of the NEC article 210.71(B)(2) requiring at least one receptacle outlet located IN the floor in meeting rooms 215 square feet and larger?
Yes, the OFR series raceway or Connectrac Express and Flex products can be utilized to comply with the requirements found in Article 210.71 of the 2017 NEC. Thank you
Date published: 2023-09-14
Is there a cover available for the end of the run? I have one that is exposed and needs a cover.
Hello Jennifer,
Yes, OFR10B is the blank end fitting to blank off the end of the run.
Thank you!
Date published: 2023-08-10
We purchased OFRBC-8R Misplaced the cover screws can we get replacements
Hello,
The part # for the cover screw accessory pack is 1009790BULK. Please contact your distributor to place an order.
Date published: 2023-06-07
I do not see the cable capacity of this raceway in your specs. A chart stating how many cat 5, cat6, cat6a, are possible per chamber would be worthwhile spec information. Due to the removable cover, this should allow 100% fill, but I don't see the info.
Please use the link below for the OFR series cutsheet. Capacity charts are on page 2. Thank you
https://legrand.webdamdb.com/directdownload.php?ti=55656453&tok=HwZkHjSikhVDo/rOFweoqQRR
Date published: 2023-02-07
Does this product meet any telecommunications EIA/TIA requirements?
Hello Tony,
There are many requirements within the standards. In order to better understand your question we'll need more specific information about the requirements you're referring to.
Feel free to email us direct. Our email address is technical.support@legrand.us
Thank you,
Date published: 2022-06-02
Is this metallic or non metallic?
Hello Brian,
The product is metallic. The base is aluminum and the cover is steel with a powder coated black finish.
Thank you
Date published: 2022-03-22
Does the product come in a lighter finish?
Hello,
The OFR series is currently only available in black.
Thanks,
Date published: 2022-03-16
Where can I get a parts catalog
Hello Michael,
Our latest catalog (2018/2019) can be downloaded from the link below on our website.
https://www.nxtbook.com/nxtbooks/wiremold/catalog1819/index.php#/p/Intro
If you have any specific questions related to Wiremold product please reach out to us direct. We can be reached by dialing 1-844-957-3783. From the main menu select option 2 for Wiremold followed by option 2 for Technical Support.
Thank you!
Date published: 2023-05-02
Hello, We'd like to specify this for a retail shop to get power from a wall to a freestanding sales counter (single duplex receptacle 20A) Can you confirm this meets applicable electrical code requirements for this application? Thank you!
Hello Architect,
Legrand Wiremold OFR Series Surface Raceway and Fittings is cETLus listed with Intertek and complies with all the requirements of Article 386 of the NEC. The OFR Series Surface Raceway and Fittings and have been tested and evaluated to UL 5 - Standard for Surface Metal Raceways and Fittings and CSA C22.2 #62 - Surface Raceway Systems.
Legrand Wiremold OFR Series Raceway was designed to comply with the Americans with Disabilities Act (ADA) Standards. In compliance with Section 303, the change in floor level does not exceed ½ inch and is beveled with a slope not steeper than 1:2. The OFR series surface raceway should not be placed in doorways and the OFR48 device boxes and transition fittings should not be placed in a path of travel.
Feel free to direct any additional questions to us at 1-844-957-3783. From the main menu select option 2 for Wiremold followed by option 2 for Technical Support.
Thank you for your interest in Legrand products!
Date published: 2022-01-12
Can you please tell me if the OFR serie can be placed under a carpet?
The National Electrical Code requires that this type of raceway is installed in such a way that is accessible. Installing it under the carpet would make it inaccessible. Therefore we don't recommend that you install it in that way.
Date published: 2021-12-22
Is there enough vertical clearance in OFRBC-8 to handle RG11 coax? If so, how many strands can it carry? Thanks.
The inside clearance of the OFR raceway is 0.38". The typical RG11 overall cable diameter is larger than that. Therefore, the RG11 cables will not fit in the OFR.
Date published: 2021-12-01
What is the difference between the OFRBC-8 and the OFRBC-8R? The product names are the same, but with different SKUs and different deoth and volume measurements
Hi Chris,
The OFRBC-8 is the commercial version sold through electrical distributors and is priced per foot. The OFRBC-8R is the retail version sold through DIY stores like Home Depot and Amazon and is priced per 8' section. Other than the pricing they are the same exact product no differences in size or appearance.
Date published: 2023-07-10
I recently had a vendor tell me this product is now end of life. Is this product end of life??? and if so is there a replacement part?
Hi Mike,
I apologize for any miscommunication from the vendor. This product is still in good standing with no intentions of being discontinued.
Date published: 2021-11-11
Do you have CAD drawings for all the OFR components to perfom CAD lay out drawings?
Good Afternoon-
Please see link for a DXF. File
https://legrand.webdamdb.com/directdownload.php?ti=55653925&tok=NqatZ0Huwt3Ssa15i3V8sQRR
Date published: 2021-05-07
How do you cut OFR and cover?
Hello and thank you for your inquiry. OFR raceway can be cut using one of the following methods;
A band saw, jigsaw and a hack saw can cut the profiles. All three types cut without any problem.
With the band saw and the jigsaw it is easier to cut the base and cover together as an assembly.
This prevents the cover from distorting. With the hacksaw, the profiles can be cut together or separately.
If using a jigsaw use a fine tooth blade.
Please reach out to us directly with any additional questions you may have. We can be reached at 1-844-957-3783. From the main menu choose option 2 for Wiremold followed by option 2 for technical support.
Date published: 2022-08-18
I see this product meets Buy American compliance, but does it also meet Buy America?
Bazaarvoice SAP Hybris Integration Version 2.8.1