Rotary 1.5A 3-Speed De-Hummer Fan Speed Control
Color White
  • Send
  • Save as PDF
  • Add to favorites Remove from favorites

Features

  • Through the use of specially designed capacitive circuitry, these units can control fans at 3- or 4-speed levels in slide, rotary, and dual styles with virtually no fan motor noise.

Specifications

General Info
Color White
Type Fan Speed Control
Finish Matte
Application Sector Multi-Dwelling Unit, Residential
Product Line Pass & Seymour
Country Of Origin Mexico
Features 3-Speed Fan Control, De-Hummer Fan Control
Number of Switches 1
Switch Type Rotary
Warranty Type Limited Lifetime Warranty
Standard CSA Listed, UL Listed
UPC Number 785007940015
Listing Agencies / 3rd Party Agencies
CSA Listed Yes
CSA File Number  48758
Technical Information
Requires Neutral Wire No
Wire Connection Type Flying Leads
Dimming Compatibility Fan Speed Only
Contact Rating 120V
Environmental Conditions Indoor Only
Frequency Rating 60 Hz
Indoor/Outdoor Indoor
Load Rating 120V 1.5A (FAN MOTOR)
Load Type AC Fan Motor
Mounting Type Wall Box
Number of Poles Single Pole
Preset No
Speed Range 3-Speed
Voltage 120 VAC
Wire Size #14 - #10 AWG

Reviews

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Questions & Answers

What adverse effects would occur if fan is on medium instead of high and one is still using the 94003 dehummer control?

Asked by: dde29
The "adverse" effect would be that the fan speeds would be all different than if used with just the de-hummer, there may even be positions on the de-hummer that fail to make the fan move. But there should not be any damage to anything, just improper operation.
Answered by: Legrand Technical Support
Date published: 2021-05-05

hello , I am looking for some fan speed controls I would like the legrand p&s de-hummer in a 3-way is that possible?

Asked by: u.p. sparky
We have a few different style of 3way De-hummer fan speed controllers and they would be used a a standard 3way switch on the other side of our 3way circuit: Rotary style - DRDH163PIV Toggle style - TSDDH163PI Decorator Style - RHDH163PTC
Answered by: Legrand Technical Support
Date published: 2021-05-05

The nut on the rotary switch shaft prohibits a standard wall plate from sitting flat against the wall. Do you have any guidance on how to overcome this problem?

Asked by: David8933
A standard Toggle style wallplate is used with the Rotary style devices and it sits on the nut without issues.
Answered by: Legrand Technical Support
Date published: 2019-11-18
  • y_2025, m_6, d_24, h_8CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_3
  • loc_en_US, sid_94003W, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_legrand
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 37ms
  • QUESTIONS, PRODUCT