radiant® Single Pole/3-Way Switch with 15A Tamper-Resistant Outlet, Nickel
RCD38TRNICC6
radiant Collection
radiant Single Pole 3 Way Switch with 15A Tamper Resistant Outlet is rated
out of
5 by
5.
Bazaarvoice SAP Hybris Integration Version 2.8.1
$27.98 USD
A step up from ordinary, this combination switch and outlet from the radiant® Collection provides convenience and flexibility, as well as style. Operable in both single-pole and 3-way applications, you can use it alone to control one light or fixture, or use with another 3-Way switch for controlling the light from two locations. Also includes a tamper-resistant outlet for safe access to the basic power every home needs. Part of the radiant® Collection, it features clean lines and a smooth finish for a sophisticated look.
Made exclusively for use with screwless Wall Plates from the radiant® Collection, sold separately.
Out of Stock on Legrand.us
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Features
- Replaces a standard switch/outlet with ease, in as little as 10 minutes.
- Offers installation flexibility, working in both single-pole and 3-way applications.
- Protects children with a patented tamper-resistant shutter system that prevents improper insertion of foreign objects, complete with "invisi-shutters" for an invisible effect.
- Features durable, high-impact resistant thermoplastic construction.
- More color options available to fit any style.
- Complete the look with a sleek, screwless radiant® Wall Plate, and coordinate with other designer switches and outlets available from the radiant® Collection.
Specifications
General Info
Product Line | Pass & Seymour | ||
Color | Nickel | ||
Finish | Metallic | ||
UPC Number | 785007055108 | ||
Country Of Origin | China | ||
Features | Combination, Locator Light | ||
Switch Type | Push | ||
Number of Switches | 1 | ||
Application Sector | Residential | ||
Standard | cULus, UL Listed | ||
Warranty Type | 1-Year Limited Warranty | ||
Type | Outlet, Switch |
Dimensions
Product Width US | 1.29 in | ||
Product Depth US | 1.59 in | ||
Product Height US | 3.81 in |
Listing Agencies / 3rd Party Agencies
cULus Listed | Yes |
Technical Information
Is Tamper-Resistant | Yes | ||
Operating Cycles | 50000 | ||
Contact Rating | 15 Amp, 120/125 VAC | ||
Number of Gangs | 1 | ||
Amperage | 15 A | ||
Number of Poles | 3-Way, Single Pole | ||
Wire Size | #14 - #10 AWG | ||
Mounting Type | Box | ||
Voltage | 120.0 V | ||
Environmental Conditions | UL94 V2 |
Resources
Cutsheet
Installation Instructions
Supporting Document
Reviews
Rated 5 out of
5
by
Gordon from
Home owner
Exactly what I needed color and all. But it does not come with the locator light even though it appears it does from picture. You have to purchase separately.
Date published: 2023-02-06
Rated 5 out of
5
by
Dave G from
Light switch/electric outlet
This device is the perfect match for a space with no receptacle nearby! It was just what I needed to add a receptacle where I already had a switch.
Date published: 2023-02-18
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
I want to use this switch to turn on lights over a vanity and have the outlet on costant... (Yes, it will be protected with a GFIC) How is it wired for this configuration?
Your HOT and NEUTRAL from the breaker get connected to the LINE side of the GFCI. One of the black leads from the switch gets connected to the LOAD HOT of the GFCI and the other black lead gets connected to the wire from your vanity light.
Radiant products
1.800.223-4162 opt 3
Mon - Fri: 8am - 8pm EST
(excluding holidays)
Email Us - tech.support@legrand.us
Date published: 2020-04-08
How do you split the circuit on switch RDC38
The RCD38TR device has a split circuit tab that can be removed from the back when connecting two HOT wires.
As shown on the attached link:
https://www.legrand.us/-/media/brands/radiant/resources/installation-instructions/radiant%20combination%20devices.ashx
Date published: 2023-06-03
Do you have the nickel color in this?
This device is available in Nickel and the model number is RCD38TRNICC6:
https://www.legrand.us/search.aspx?q=rcd38trnicc6
Date published: 2020-04-06
How do I wire a 3 way switch and outlet combination with 4 wires? Black/Hot, Black/Transfer, Red/Transfer, Copper/Ground. I have tried several different ways and either I get the switch to work but the outlet is not energized.
The receptacle will also require a Neutral(white wire) connected to the NEU B terminal.
Date published: 2020-02-25
Is this available in Dark Bronze?
Yes, the model number for this device in Dark Bronze is RCD38TRDBCC6:
https://www.legrand.us/search.aspx?q=RCD38TRDBCC6
Date published: 2020-02-03
Which snap-in light module would I order with this switch+outlet combo? I just bought the RCD38TRWCC6. I presume the "Legrand" logo lights up with the module? Thanks!
The Light Module for the Radiant combination switch is RCDLM and it will illuminate the small opening at the top of the switch so you can find it in the dark:
https://www.legrand.us/search.aspx?q=rcdlm
Date published: 2019-05-02
How do I wire the Legrand radiant three way combination switch so the switch operates as a three way but the outlet always stays on?
Hello Mike. I just bought this switch+Outlet for my coffee machine to have a switchable outlet (rather than unplug it all the time since the coffee machine doesn't have a power button). I confirm that the user guide included in the box, describes with a clear diagram your setup with three way control and permanent outlet so it will support it. You only need another three way compatible switch with Hot/Black, Load/White and Red wire inputs. Unfortunately I can't upload a scan picture. Greg
Date published: 2019-11-13
Planning to plug undercabinet lights to the receptacle outlet, switched from the switch. Hence the switch needs to operate the receptacle. Do you have a diagram for that?
The wiring diagram is attached for the Radiant RCD38TRW so the switch controls the power to the receptacle.
Date published: 2020-09-07
I'm trying to replace a single light switch with the combo switch and receptacle, I have a black, white, and a ground wire. I currently have it wired and the light switch works but not the plug. Do I need to splice a wire in somewhere? Diagram no help
Good Morning,
You will need to run a jumper between the bundle of white Neutral wires and the silver screw next to the outlet. If you don't have a bundle of neutrals, you won't be able to use this kind of device in the box unless you run a new one separately.
Hope this helps
Date published: 2020-05-20
Trying to wire this up 1 pole. I have a black red white and ground wires. Where does which one go? Keep tripping the breaker how I assume it gets wired
The instructions enclosed with the RCD38TRW switch contain wiring diagrams which would answer your question. If you need an additional copy of the instructions you can download a new set from our website by entering the RCD38TRW number in the search window and then by clicking on the resources drop down or you could call 1-800-223-4162 opt 3 for assistance.
Date published: 2019-09-29
Old House Ony three wires to the switches in the bathroom 2 way switch Can the legrand paddle switch with outlet be hooked up in place of one of the switches? bought rcd38trwcc6
To properly wire the RCD38TR as a 3way switch(with outlet), you need at least 4 wires(not counting Ground wire)...see attached wiring diagram.
Date published: 2020-07-11
can you forward that diagram
The attached shows the single pole and 3way wiring diagrams for the Radiant Combination device, RCD38TR.
Date published: 2020-06-02
How do you remove the split circuit tab? The switch doesn’t seem to match the picture shown in the instructions.
On the lower right of the device between the two black screws there is a small tab that you can pull out with a small pliers.
Date published: 2022-01-03
Do you sell 20 Amp switches and plugs for a kitchen that compliment the brushed nickel screwless wall plates
We do not make a 20A version of the RCD38TRNicc6 But You can put this on a 20A circuit
Date published: 2018-08-16
Trying to wire 3 way legrand radiant switch where power and light fixture wires are at same switch and remaining switch only has 14-3 feeding it. This is different than your example. Can you send me the alternative diagram? Thanks
This is a way to make this work as long as the switch with the outlet is going on the hot end of the circuit where the hot/common is coming from the box. I have attached a diagram to illustrate how this would work. Basically the hot wire would attach to the hot terminal on the first switch where the 14/3 is running FROM. The red and black wires in the 14/3 would serve as travelers to the dead end three way switch that the 14/3 is running TO. Then the white wire could be marked with black tape and be used to run from the load on the dead end switch to load wire up to the light in the first box. These wires would pig tail together.
Date published: 2019-09-29
Bazaarvoice SAP Hybris Integration Version 2.8.1
You may also like...
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
NTL873WCC6 | radiant Collection
Add a little light where you need it, with this combination switch and night light.
$24.04
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
RH703PTUTCCCV4 | radiant Collection
The most stylish and versatile dimming solution, compatible with virtually any dimmable bulb.
$65.94
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
RT2WCCV4 | radiant Collection
4-button digital timer switch
$29.42
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
RRW600UTCCCV4 | radiant Collection
Turn the lights on and off, automatically, with this convenient occupancy sensor.
$33.39