DLM Zone Controller, Scheduler and Network Interface
LMZC-301
Wattstopper
Bazaarvoice SAP Hybris Integration Version 2.8.1
The LMZC-301 zone controller provides power and connectivity to Digital Lighting Management (DLM) fixture controllers as well as switches, occupancy sensors, daylight sensors, and input modules. It is the foundation of a DLM local network for fixture controllers, and includes integral segment network connectivity. The zone controller can be used to enable the automation of lighting functions across a facility.
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Features
- Runs scheduled and photocell events autonomously
- Easy setup via LMCT-100-2 handheld configuration tool
- Ideal power supply for DLM fixture controllers; supports up to 64 connected loads
- Native BACnet communications for network control solutions
- 99 control groups accessible via handheld configuration tool
- Compatible with Digital Lighting Management load controllers, switches, sensors and input devices
Specifications
General Info
Color | Black, Silver | ||
Type | Network Controller | ||
Application Sector | Commercial | ||
Product Line | Wattstopper | ||
Country Of Origin | United States | ||
Installation Location | Above Ceiling, Network Rack, Wall | ||
Warranty Type | 5-Year | ||
Standard | UL 2043, cUL, FCC part 15, RoHS | ||
UPC Number | 754182938674 |
Dimensions
Product Depth US | 5.75 in | ||
Product Height US | 10.0 in | ||
Product Width US | 17.125 in |
Additional Information
Security | Yes | This product is ioXt certified |
Technical Information
Number of Connections | 2 | ||
Topology | Free Topology | ||
Wire Connection Type | RJ-45, Terminal Block | ||
Compatibility | DLM Wired | ||
Indoor/Outdoor | Indoor | ||
Input Voltage | 115/277 VAC | ||
Line Frequency | 60 Hz | ||
Mounting Type | Screw Holes | ||
Number of Relays | 0 | ||
Operating Temperature | 0°-40°C, 32°-104°F | ||
Operating Temperature Max | 104 °F | ||
Operating Temperature Min | 32 °F | ||
Operating Humidity | 5-95% RH (Non-Condensing) | ||
Output Voltage | 24 VDC | ||
Bus Power Supply | 250 mA @ 24 VDC, Class 2 | ||
Storage Temperature | 23° - 176° F |
Resources
Cutsheet
Installation Instructions
Instruction Sheet
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
Why is it that I can program on and off schedules with an LMCT-100-2 with firmware version 6.14 and not with 6.35?
There are no known issues with LMCT-100-2 firmware version 6.35. The primary difference between versions 6.14 and 6.35 is the menu structure, which may affect how certain settings are accessed or configured. For assistance in navigating the updated interface or diagnosing the issue further, we recommend contacting Wattstopper Technical Support.
Date published: 2025-04-17
How do I program the LMZC board with the LMCT100-2 to turn lights on and off by schedule only.
To program the LMZC-301 for scheduled lighting control using the LMCT-100-2, follow these basic steps:
🔹 Navigate to Group Setup, and under Group Loads, assign your desired load(s) to a group.
🔹 Go to Panel Setup to set the LMZC’s Date and Time.
🔹 In Location Settings, configure the appropriate Location. (Used for Astro schedules)
🔹 Proceed to Panel Programming and select Schedules.
🔹 Create two events (one for LNZ and one for TURN OFF) and assign them to your group.
These steps establish basic scheduling functionality. For more detailed, site-specific assistance, please contact Wattstopper Technical Support.
Date published: 2025-04-17
Where can I purchase this in toronto
Salex Lighting Under Control is the Sales Rep in the Toronto Area
Date published: 2024-11-26
Can I get a pdf of the Bacnet points? The plan is to interface to a BMS
Please reach out to our tech. support team for further assistance troubleshooting this issue.
Legrand Technical Support:
Phone: 1 800-879-8585, Option 3 then Option 1
Mon - Fri: 7am - 7pm CST (excluding holidays)
Date published: 2023-04-20
Can we control the LMZC via TCP/IP Commands? If so, what port number is used?
Hi Ronnie,
Please reach out to our tech. support team for further assistance with this product.
Legrand Technical Support:
Phone: 1 800-879-8585, Option 1
Mon - Fri: 7am - 7pm CST (excluding holidays)
Date published: 2024-04-17
OurLMZC-301 seams to have lost the photocell input, that controls it. I have a LMCI-100 to look at the device, but dont't know if i'm connected correctly, because I can't see anything. Please advise
Hello, the LMZC-301 is compatible with our LMCS software. You can find the direct download on our website Legrand.us, once downloaded we can use a cat5e cable between the A/B ports on the LMZC to the LMCI, then USB to Laptop. Once connected, at the bottom right it should show "connected".
If further assistance is needed please call Wattstopper Tech Support 1-800-879-8585
Date published: 2022-12-13
How does the cable between an internally-mounted LMPB-100 and the "A" RJ45 port need to be?
It is a standard cat6 cable and needs to be 8-12" long.
Date published: 2022-12-13
on the LMZC, are there any issues with using LMPD port 3&4 instead of 1&2
The LMZC-301 has four LMPD ports which are use to power up the LMRD board on a panel. The only reason there a four is because the maximum amount of LMRD boards on a panel is four so it doesn't matter which one you use they all work the same.
Date published: 2022-12-13