Wattstopper’s CI-300 Passive Infrared (PIR) Ceiling Sensors automatically turn lighting on and off based on occupancy. The sensor mounts on the ceiling with a flat, low-profile appearance and provides 360 degrees of coverage.
Contact Rating 1 A @ 30 VDC/VAC
Footprint 500 sq ft
  • Send
  • Save as PDF
  • Add to favorites Remove from favorites

Features

  • Architecturally appealing low-profile appearance
  • Automatic or manual-on operation when used with a BZ-150 Power Pack
  • Plug terminal wiring for quick and easy installation
  • Accepts low-voltage switch input for manual-on operation
  • Walk-through mode increases savings potential
  • 360° coverage

Specifications

General Info
Product Line Wattstopper
UPC Number 754182914296
Country Of Origin China
Features Indicator Lights, IR (Infrared), Motion Sensor
Application Sector Commercial
Warranty Type 5-Year
Dimensions
Product Width US 4.0 in
Product Weight US 0.5 lb
Product Volume US 48.0 cu in
Product Depth US 4.0 in
Product Height US 3.0 in
Additional Information
RoHS Conformant Yes This product meets the material restrictions of Article 4 of the RoHS Directive (2011/65/EU), including Commission Delegated Directive 2015/863.
DesignLights Consortium Qualified System Yes
Security   Yes This product is ioXt certified
Product Environmental Profile Yes
Technical Information
Sensor Type Occupancy
Amperage 20 A
Indicator LED Light
Voltage 24 V
Connection Type Wired

Resources

CAD Drawings
57-003-4 - 8-Wire Occupancy Sensor with Manual-On Feature
dwg
57-003-4 - 8-Wire Occupancy Sensor with Manual-On Feature
png
57-003-4 - 8-Wire Occupancy Sensor with Manual-On Feature
dxf
57-010 - Multiple Occupancy Sensors Using One Power Pack
dxf
57-010 - Multiple Occupancy Sensors Using One Power Pack
png
57-010 - Multiple Occupancy Sensors Using One Power Pack
pdf
57-010 - Multiple Occupancy Sensors Using One Power Pack
dwg
57-039-11 - MB-1 Mounting Information using CI-Series Sensors
png
57-039-11 - MB-1 Mounting Information using CI-Series Sensors
dwg
57-039-11 - MB-1 Mounting Information using CI-Series Sensors
dxf
57-039-8 - CI,DT,UT-355 Sensor Mounting Details
png
57-039-8 - CI,DT,UT-355 Sensor Mounting Details
dxf
57-039-8 - CI,DT,UT-355 Sensor Mounting Details
dwg
57-039-8 - CI,DT,UT-355 Sensor Mounting Details
pdf
57-303 - CI, DT, UT-305 Standard Schematic
png
57-303 - CI, DT, UT-305 Standard Schematic
dxf
57-303 - CI, DT, UT-305 Standard Schematic
pdf
57-303 - CI, DT, UT-305 Standard Schematic
dwg
60-601-2 - LI/LP Relay Panels Occupancy Sensor Connection
pdf
60-601-2 - LI/LP Relay Panels Occupancy Sensor Connection
dxf
60-601-2 - LI/LP Relay Panels Occupancy Sensor Connection
png
60-601-2 - LI/LP Relay Panels Occupancy Sensor Connection
dwg
CI-300
dxf
CI-300
png
CI-300
dwg
CI-300-1
png
CI-300-1
dxf
CI-300-1
dwg
CI-300-1cp - CI-300-1 Coverage Pattern
dwg
CI-300-1cp - CI-300-1 Coverage Pattern
dxf
CI-300-1cp - CI-300-1 Coverage Pattern
png
CI-300cp - CI-300 Coverage Pattern
dwg
CI-300cp - CI-300 Coverage Pattern
dxf
CI-300cp - CI-300 Coverage Pattern
png
CI-305
dwg
CI-305
dxf
CI-305
png
CI-305-1
dxf
CI-305-1
dwg
CI-305-1
png
CI-305-1cp - CI-305-1 Coverage Pattern
dxf
CI-305-1cp - CI-305-1 Coverage Pattern
dwg
CI-305-1cp - CI-305-1 Coverage Pattern
png
CI-305cp - CI-305 Coverage Pattern
dwg
CI-305cp - CI-305 Coverage Pattern
png
CI-305cp - CI-305 Coverage Pattern
dxf
View More

Reviews

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 9ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Questions & Answers

I have CI-305 sensors in an office space. The lights in this office space go out every 30 minutes (assuming that no one moves from their desks in that time). Is there an option to change the timer from 30 minutes to a longer period of time?

Asked by: Chris
Hello, The CI-305 will have the following time delay settings - Time Delay Adjustment 30 seconds to 30 minutes. Best Regards, Technical Support
Answered by: Justin
Date published: 2023-10-18

Does the CI 300 or CI 305 work with the BZ-50 power pack?

Asked by: Anonymous
Yes, both the CI-300 and CI-305 are both 24v sensors and are compatible with BZ-50 power packs.
Answered by: Tier 1 Tech Support
Date published: 2023-05-18

Can the CI-300 be used with a Dimmer Switch like DCLV-2 and be set to manual on and auto off? How would these be wired? Each of these devices are showing a different wiring for the control/sensor blue wiring

Asked by: EricVet
Please reach out to our tech. support team for further assistance with this wiring issue. Legrand Technical Support: Phone: 1 800-879-8585, Option 3 then Option 1 Mon - Fri: 7am - 7pm CST (excluding holidays)
Answered by: Tier 1 Tech Support
Date published: 2023-03-27

I would like to know if this kind sensor is suitable for hallways 5-10feet wide. Do you any have documented case in order to evaluate the sensor response in that particular case? Thank you very much.

Asked by: Anonymous
Hi, The WT-2255 is a better suited sensor for hallway applications. It has a coverage pattern of 10 feet wide by 90 feet long. Please visit the product page or reach out to our tech. support team for further assistance if required. Legrand Technical Support: Phone: 1 800-879-8585, Option 3 then Option 1 Mon - Fri: 7am - 7pm CST (excluding holidays)
Answered by: Tier 1 Tech Support
Date published: 2023-03-27
  • y_2024, m_3, d_27, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.38
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_4
  • loc_en_US, sid_CI-300, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_legrand
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 42ms
  • QUESTIONS, PRODUCT