DLM Dual Tech Ceiling Mount Sensor V4, White
LMDC-100
Wattstopper
Bazaarvoice SAP Hybris Integration Version 2.8.1
The LMDC-100 low profile Dual Technology Ceiling Mount Occupancy Sensor uses both passive infrared (PIR) and ultrasonic technologies to achieve precise occupancy sensing for energy-efficient control of lighting and plug loads. It is a digital sensor, and is part of a Wattstopper Digital Lighting Management (DLM) system.
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Features
- Plug n’ Go™ automatic configuration for quick installation and maximum energy savings
- Push n’ Learn™ functionality for customization without the need for tools or a PC
- Digital Lighting Management components plug together on a free-topology Category 5e DLM local network
- Infrared (IR) transceiver for wireless configuration and control
- Ultrasonic diffusion technology spreads coverage to a wider area (patented); 40KHz signal
- 360 degree PIR coverage
- Detection Signature Processing eliminates false triggers and provides immunity to RFI and EMI
Specifications
General Info
Color | White | ||
Product Series | LMDC-100 | ||
Type | Sensor | ||
Finish | Matte | ||
Application Sector | Commercial | ||
Product Line | Wattstopper | ||
Country Of Origin | China | ||
Features | Adjustable Time Delay, Indicator Lights, Load Controller Required, Sensitivity Adjustment | ||
Included | Spring Clips | ||
Installation Location | Ceiling | ||
Warranty Type | 5-Year | ||
Standard | UL, cUL, FCC part 15, RoHS, PEP | ||
UPC Number | 754182926329 |
Dimensions
Product Depth US | 2.1 in | ||
Product Height US | 4.5 in | ||
Product Volume US | 44.55 cu in | ||
Product Width US | 4.5 in | ||
Product Weight US | 0.2 lb |
Additional Information
RoHS Compliant | Yes | This product meets the material restrictions of Article 4 of the RoHS Directive (2011/65/EU), including Commission Delegated Directive 2015/863. |
Technical Information
Current Draw | 20 mA | ||
On Function | Auto On | ||
Topology | Free Topology | ||
Wire Connection Type | RJ-45 | ||
Compatibility | DLM Wired, Infrared Wireless | ||
Has Battery | No | ||
Indoor/Outdoor | Indoor | ||
Input Voltage | 24 VDC | ||
Mounting Type | 4 in Octagonal J-Box, Ceiling Tile, Surface | ||
Number of Buttons | 0 | ||
Timer Type | Digital | ||
Timer Duration | 5-30 Minutes | ||
Operating Temperature | 0°-40°C, 32°-104°F | ||
Operating Temperature Max | 104 °F | ||
Operating Temperature Min | 32 °F | ||
Operating Humidity | 5-95% RH (Non-Condensing) | ||
Sensing Range | 25 x 25 ft, 32 ft diameter | ||
Sensor Type | Occupancy | ||
Sensor Technology | Dual Technology, Passive Infrared (PIR), Ultrasonic | ||
Sensor Coverage | 1000 sq ft | ||
Sensor Coverage Pattern | 360 deg | ||
Sensor Mounting Height | 10 ft | ||
Ultrasonic Frequency | 40 kHz | ||
Storage Temperature | 23° - 176° F, -5° - 80° C | ||
Engraving Type | Blank |
Resources
Cutsheet
Installation Instructions
CAD Drawings
90-511 - LMDC-100 Dimension and Mounting
dwg
90-511 - LMDC-100 Dimension and Mounting
dxf
90-511 - LMDC-100 Dimension and Mounting
pdf
90-511 - LMDC-100 Dimension and Mounting
png
LMDC-100 Symbol
dwg
LMDC-100 Symbol
dxf
LMDC-100 Symbol
png
LMDC-100cp - LMDC-100 Coverage Pattern
dwg
LMDC-100cp - LMDC-100 Coverage Pattern
dxf
LMDC-100cp - LMDC-100 Coverage Pattern
png
View More
Unknown
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
I would like to use the ccupancy sensors to track the sole-occupier movements throughout a 2-strorey maisonette. If this is possible, I would then like to control lighting, HVAC, audio and video based on the presence of the occupier.
The Wattstopper DLM system natively controls lighting and uses BACnet communication to integrate with a Building management system to control HVAC and AV. Please contact your local Wattstopper Rep to help you design a system that will work with your specific needs.
Date published: 2024-03-28
Can the occupancy sensors be daisy chained if the light fixtures are working off the same switch, but the light fixtures have there own individual occupancy sensor?
Yes, they can be daisy chained - the load binding is determined by programming, not by the cat5 wiring.
Date published: 2024-01-26
Does LMDC 100 motion sensor work through glass.?
Anil,
Ultrasonic sound waves do not penetrate solid objects well and the PIR sensor cannot "see" through glass because this signature cannot travel through it. Some of this depends on the type of glass used in the window like thinner glass, we have cases where the sensitivity is lowered and it works and some where the sensor needs to be relocated.
Date published: 2024-01-25
Is the LMDC-100 still a live sku that is available to order?
Hi Jeff,
The LMDC-100 sensor is readily available for purchase and has a UPC code of 754182926329.
Date published: 2024-05-17
Can LDDc-100 be programmed to function as vacancy sensor?
Greetings,
Yes the LMDC-100 can be programmed to function as Auto-on/Auto-off or Manual-on/Auto-off. These setting changes can be achieved via our LMCT-100-2 IR programming Tool.
Date published: 2024-01-18
wheres the push and learn button located for the lmdc-100
Hi Jay,
Please refer to the instruction sheet available for download on the product page for button push sequences to adjust the sensor or reach out to tech support for more assistance.
Legrand Technical Support:
Phone: 1 800-879-8585, Option 3 then Option 1
Mon - Fri: 7am - 7pm CST (excluding holidays)
Date published: 2023-04-20
what is the sensor range?
Hi,
The sensor coverage pattern is as shown below.
Date published: 2024-01-22
Does the sensor provide data as to how often the area is occupied? If not, do any of your products provide occupancy data?
Hi Eric,
This sensor does not have that feature. An advanced DLM system with BMS capabilities can provide more details regarding occupancy and power consumption.
Please reach out to our tech. support team if further assistance is required with this request.
Legrand Technical Support:
Phone: 1 800-879-8585, Option 3 then Option 1
Mon - Fri: 7am - 7pm CST (excluding holidays)
Date published: 2023-03-07
when scrolling through the functions, i do not see the overide function.the lights keep timing out, and i would like to overide this function.
Hello Mike,
Please reach out to our Wattstopper division for further assistance with part number LMDC-100.
Wattstopper Technical Support:
Phone: 1800-879-8585, Option 1
Mon - Fri: 7am - 7pm CST (excluding holidays)
Best Regards,
P&S Technical Support
Date published: 2022-10-28
Can the LMDC-100 occ sensor be wall mounted, stairwell application
If you mount a ceiling sensor to a wall, it will effect the way motion is detected and may not work properly.
Date published: 2022-10-24
hi i ran cat6 cable is that going to affect the installation, or it need to be cat5
Good morning
Any Cat5 or Cat6 cable will work with the DLM installation as long as the cable is a straight thru cable. Although you can use the TIA standard 568A, TIA standard 568B is what I recommend.
Date published: 2022-09-15
Where is the .pdf instructions to program the V3 with LCD screen?
Good morning
To be able to answer your question we will need what the device is you are refering to. It would be best to contact Wattstopper Tech Support at 1-800-879-8585 option#1 for us to gather more information to help help answer your question.
Date published: 2023-09-30
I have a LMDC-100 showing E06 & E07 on the lcd display. It seems to over ride the two switches in the room. What are these codes and is there a master rest to get rid of them?
These are DLM error codes. E06: No load assigned to sensor, E07: No communication possible(Comm line is being grounded). There is a Cat5 termination issue, and a some programming needed once the Cat5 issue is resolved.
Date published: 2024-10-07
Is the LMDC-100 designed to function in low-movement settings such as conference or meeting rooms where people are always seated? Does that affect the installation height? We want to avoid lights shutting off during meetings where there isn't movement.
The LMDC-100 is an occupancy sensor. It's main function is to trigger on the load when it detects motion and keep the load on as long as it detects motion. It also will to turn off the load when it doesn't detect a motion after the time delay expires. If someone feels that it may turn off the load because people are not moving it's recommend to set the time delay to 30 minutes which is the maximum. Outside of maximizing the time delay you can put the sensor into override mode which will not allow it to use the time delay, plus the two technologies like the PIR and Ultrasonic within the sensor will no longer function and the sensor will not respond to movement or lack of movement but you will have to use a switch to turn on and off the lights because the sensor is dormant.
Date published: 2022-06-13
What is max mounting height above finish floor for the sensor LMDC-100 – U ? We intend to install LMDC-100 – U sensor to a pendant. The bottom of the mounting box is 12'-4" AFF. Is this mounting height acceptable?
The maximum mounting height for an LMDC-100 is 10 feet. It is recommended that you use an LMPC-100-5 sensor for ceiling heights from 10-40ft.
https://www.legrand.us/lighting-controls-and-systems/occupancy-and-vacancy-sensors/ceiling-wall-mount-occupancy-sensors/dlm-pir-ceiling-mount-sensor-with-extended-height-lens/p/lmpc-100-5
Date published: 2022-02-01
Lights won’t turn on or off automatically using this sensor . I am using compatible switch .
There may be an issue with the programming. Please contact Wattstopper Technical Support @ 800-879-8585 for troubleshooting assistance.
Date published: 2022-08-27
What is the pin out for the RJ45 connections? Does this use the same pinout as Cat5E network cables?
568B is the recommended pin out for Cat5 cables being used with the DLM system.
Date published: 2022-03-29
Is there an available specification requirements sheet for the LMDC-100 Dual Technology Ceiling Sensor comparable to the specifications sheet for the DW-100 Dual Technology Wall Switch Sensor document #DW0608?
All of the spec info for the LMDC-100 Sensors would be included in the Cutsheet and Installation Instructions located at:
https://www.legrand.us/lighting-controls-and-systems/occupancy-and-vacancy-sensors/ceilingwall-mount-occupancy-sensors/dlm-dual-tech-ceiling-mount-sensor/p/lmdc-100?text=LMDC-100
Date published: 2022-02-06
We have 3 LMDC-100s daisy chained together and only the first one is operational. I don't see any documentation on this type of setup. Is this a valid configuration?
Yes, the DLM system is an open topography system and it is perfectly fine to wire in that configuration. Please call Technical Support @ 800-879-8585 if you require troubleshooting assistance.
Date published: 2021-08-03
Where can I find the guide on how to adjust the settings on the dclm 100?
I have attached the DLM System Installation Guide. Pages 8-21 cover the installation and programming of the DLM sensors. I hope this helps.