Dual Tech Occupancy Sensor 100 -347 VAC, center mount 360°
DT-355
Wattstopper
Bazaarvoice SAP Hybris Integration Version 2.8.1
Wattstopper’s low profile DT-355 dual technology occupancy sensor combines the benefits of passive infrared (PIR) and ultrasonic technologies. The sensor mounts on the ceiling with a flat, unobtrusive appearance and provides 360 degrees of coverage.
BAA
No
- No
- Yes
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Specifications
General Info
Color | White | ||
Product Series | DT-355 | ||
Type | Sensor | ||
Finish | Glossy | ||
Application Sector | Commercial | ||
Product Line | Wattstopper | ||
Country Of Origin | China | ||
Features | Adjustable Time Delay, Indicator Lights, Light Level Sensor, Sensitivity Adjustment, Test Mode, Walkthrough Mode | ||
Included | Mounting Screws, Sensor Mask | ||
Installation Location | Ceiling | ||
Switch Type | Motion Sensor | ||
Warranty Type | 5-Year | ||
Standard | UL, cUL | ||
UPC Number | 754182913848 |
Dimensions
Product Depth US | 1.5 in | ||
Product Height US | 4.5 in | ||
Product Volume US | 44.4 cu in | ||
Product Width US | 4.5 in | ||
Product Weight US | 0.2 lb |
Additional Information
Product Environmental Profile | Yes | ||
RoHS Compliant | Yes | This product meets the material restrictions of Article 4 of the RoHS Directive (2011/65/EU), including Commission Delegated Directive 2015/863. |
Technical Information
On Function | Auto On | ||
Wire Connection Type | Flying Leads | ||
Compatibility | BZ Power Packs, Wattstopper PLUS Sensor Interface Module | ||
Has Battery | No | ||
Indicator | LED Light | ||
Indoor/Outdoor | Indoor | ||
Input Voltage | 120/230/277/347 VAC | ||
Line Frequency | 50 Hz, 60 Hz | ||
Load Rating | 1200 W @ 230-347 VAC, 800 W @ 120 VAC | ||
Mounting Type | 2-1/4 in Deep J-Box, 4 in Octagonal J-Box, Surface | ||
Number of Buttons | 0 | ||
Timer Type | DIP Switch | ||
Timer Duration | 30 Seconds, 5-30 Minutes | ||
Operating Temperature | 0°-55°C, 32°-131°F | ||
Operating Temperature Max | 131 °F | ||
Operating Temperature Min | 32 °F | ||
Operating Humidity | 5-95% RH (Non-Condensing) | ||
Sensing Range | 36 ft | ||
Sensor Type | Occupancy | ||
Sensor Technology | Dual Technology, Passive Infrared (PIR), Ultrasonic | ||
Sensor Coverage | 1000 sq ft | ||
Sensor Coverage Pattern | 360 deg | ||
Sensor Mounting Height | 8-12 ft | ||
Ultrasonic Frequency | 40 kHz | ||
Storage Temperature | 23° - 176° F, -5° - 80° C | ||
Engraving Type | Blank |
Resources
Installation Instructions
CAD Drawings
57-039-9 - CI,DT,UT-300 Sensor Mounting Details
dxf
57-039-9 - CI,DT,UT-300 Sensor Mounting Details
dwg
57-039-9 - CI,DT,UT-300 Sensor Mounting Details
png
57-039-9 - CI,DT,UT-300 Sensor Mounting Details
pdf
57-301 - DT-355 Standard Schematic
pdf
57-301 - DT-355 Standard Schematic
png
57-301 - DT-355 Standard Schematic
dxf
57-301 - DT-355 Standard Schematic
dwg
57-303 - CI, DT, UT-305 Standard Schematic
png
57-303 - CI, DT, UT-305 Standard Schematic
pdf
57-303 - CI, DT, UT-305 Standard Schematic
dxf
57-303 - CI, DT, UT-305 Standard Schematic
dwg
DT-355
dxf
DT-355
png
DT-355
dwg
DT-355cp - DT-355 Coverage Pattern
png
DT-355cp - DT-355 Coverage Pattern
dxf
DT-355cp - DT-355 Coverage Pattern
dwg
View More
Product Environmental Profile
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
Is there an ambient temperature rating for the DT355? Have a customer looking for a cold temperature rated line voltage ceiling sensor. Not outdoors.
Hello JB,
Please review the following information regarding the operating temperature for part DT-355.
Operating Temperature 32° to 131°F (0° to 55°C)
Best Regards,
Technical Support
Date published: 2023-04-03
Can a switch or relay be added to keep these on during working hours and back to normal when after working hours?
Hi Jeff,
Sorry no, this sensor does not allow for work hours/night control. For more advanced sensor timing control you might want to consider the DLM line of products where this is achievable.
Date published: 2024-08-02
I’m having issues getting the DT-355 to function properly after installing a new DT-355. Can you explain the function of the (light level and the ultrasonic sensitivity) features?
Hi Ben,
Please reach out to our tech. support team for further assistance with programming the DT-355 or refer to the resources section of each product for cut sheets and detailed instructions for activating or de-activating product features.
Legrand Technical Support:
Phone: 1 800-879-8585, Option 3 then Option 1
Mon - Fri: 7am - 7pm CST (excluding holidays)
Date published: 2023-03-07
One of the answers to a question asked previously was that a DT-355 Line voltage sensor could be combined with a Radiant 0-10V dimmer on the load side. Is this correct? I am about to order this combination of devices and I want to make sure.
Hello John,
Yes, you can utilize a radiant 0-10v dimmer on the load side of the DT-355 sensor. Please feel free to give us a call if you would like to discuss this configuration further.
legrand Contact information:
Phone #: 844-957-3783 - Option 1, followed by option 2 for Technical Support.
Monday - Friday | 8:00am - 6:00pm Eastern Standard Time (excluding holidays)
Best Regards,
Technical Support
Date published: 2022-10-25
Can a dimmer switch be incorporated with the occupancy sensor to dim the lights when needed?
Yes, a line voltage switch/dimmer can be added to the load side of the DT-355.
Date published: 2024-04-19
Do you have a sensor rated to 0F ?
The CB-100 is a PIR only sensor, which can operated -40 to 95F.
Please view attached SPEC sheet
Date published: 2022-10-11
can these occupancy sensors be utilized in a cleanroom setting? specifically ISO 5-9 rated cleanrooms
No, our sensors are not cleanroom certified.
Date published: 2022-06-01
What is the maximum distance the occupancy sensor can be from the ground for it to work properly
The DT-355 is designed for a ceiling heights of about 8-12 feet from the floor.
Date published: 2022-10-11
Does this sensor cover minor motion? If so, what are the distances for that?
The DT-355 is a Dual-Technology sensor that has both PIR and Ultrasonic technology built in . The sensor is able to detect major and minor motion up to 1000 sqft when mounted below 10'.
Date published: 2022-02-02
We have these thru out our warehouse, but would like the one by the entry door to stay on, is that possible?
To override all sensor functions on the DT-355, set the Ultrasonic Sensitivity trimpot to the fully counterclockwise (Service) position.
This bypasses the occupancy control functions of the sensor.
Date published: 2024-11-12
Hello, is the DT-355 sensor rated for exhaust fans?
No, the DT-355 has no rating for motor loads. I suggest looking at our BZ power packs and a 24v low voltage sensor. BZ power packs are rated for motor loads.
Date published: 2023-06-08
Comparing with the other product Ultrasonic Ceiling Occupancy Sensor, 24VDC (W-500A), which sensors would be more suitable for a 150sq.m classroom? Comparing to its technologies, lifetime and price. Thank you.
Dual technology sensors are most commonly used in this application. They work using a combination of PIR and Ultrasonic technology. As individuals move throughout a given space, Ultrasonic wave analysis and the Doppler effect help detect indirect motion while passive infrared sensors monitor presence directly.
Date published: 2021-07-26
we are looking for an occupancy sensor that will fit in a single gang electrical box. do you offer one?
Good Afternoon,
Thank you for contacting Wattstopper. We offer several sensor switch options that will fit in a single gang electrical box. Please go to our website www.legrand.us and you can search Wall Switch Sensors. We do not have an option that is a sensor only. The correct device for your situation will depend on your application and if you want a line voltage or low voltage sensor. Please let us know if we can offer any further assistance.
Best Regards,
Wattstopper Technical Support
800-879-8585
Date published: 2021-07-20
Can you use two ceiling sensor in a large room ?
Yes, multiple ceiling sensors can be used to cover a large area.
Date published: 2022-12-06
Bazaarvoice SAP Hybris Integration Version 2.8.1