Dual Tech Occupancy Sensor 100 -347 VAC, center mount 360°

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getAggregateRating, 40ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Wattstopper’s low profile DT-355 dual technology occupancy sensor combines the benefits of passive infrared (PIR) and ultrasonic technologies. The sensor mounts on the ceiling with a flat, unobtrusive appearance and provides 360 degrees of coverage.

BAA No
  • Send
  • Save as PDF
  • Add to favorites Remove from favorites

Features

  • Architecturally appealing low profile appearance
  • Ultrasonic diffusers give more comprehensive coverage
  • Operates at 120, 230 (single phase), 277 or 347 VAC, 50/60 Hz
  • Terminal wiring for quick and easy installation
  • Walk-through mode increases savings potential

Specifications

General Info
Color White
Product Series DT-355
Type Sensor
Finish Glossy
Application Sector Commercial
Product Line Wattstopper
Country Of Origin China
Features Adjustable Time Delay, Indicator Lights, Light Level Sensor, Sensitivity Adjustment, Test Mode, Walkthrough Mode
Included Mounting Screws, Sensor Mask
Installation Location Ceiling
Switch Type Motion Sensor
Warranty Type 5-Year
Standard UL, cUL
UPC Number 754182913848
Dimensions
Product Depth US 1.5 in
Product Height US 4.5 in
Product Volume US 44.4 cu in
Product Width US 4.5 in
Product Weight US 0.2 lb
Additional Information
Product Environmental Profile Yes
RoHS Compliant Yes This product meets the material restrictions of Article 4 of the RoHS Directive (2011/65/EU), including Commission Delegated Directive 2015/863.
Technical Information
On Function Auto On
Wire Connection Type Flying Leads
Compatibility BZ Power Packs, Wattstopper PLUS Sensor Interface Module
Has Battery No
Indicator LED Light
Indoor/Outdoor Indoor
Input Voltage 120/230/277/347 VAC
Line Frequency 50 Hz, 60 Hz
Load Rating 1200 W @ 230-347 VAC, 800 W @ 120 VAC
Mounting Type 2-1/4 in Deep J-Box, 4 in Octagonal J-Box, Surface
Number of Buttons 0
Timer Type DIP Switch
Timer Duration 30 Seconds, 5-30 Minutes
Operating Temperature 0°-55°C, 32°-131°F
Operating Temperature Max 131 °F
Operating Temperature Min 32 °F
Operating Humidity 5-95% RH (Non-Condensing)
Sensing Range 36 ft
Sensor Type Occupancy
Sensor Technology Dual Technology, Passive Infrared (PIR), Ultrasonic
Sensor Coverage 1000 sq ft
Sensor Coverage Pattern 360 deg
Sensor Mounting Height 8-12 ft
Ultrasonic Frequency 40 kHz
Storage Temperature 23° - 176° F, -5° - 80° C
Engraving Type Blank

Reviews

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Questions & Answers

Is there an ambient temperature rating for the DT355? Have a customer looking for a cold temperature rated line voltage ceiling sensor. Not outdoors.

Asked by: JB
Hello JB, Please review the following information regarding the operating temperature for part DT-355. Operating Temperature 32° to 131°F (0° to 55°C) Best Regards, Technical Support
Answered by: Justin
Date published: 2023-04-03

Can a switch or relay be added to keep these on during working hours and back to normal when after working hours?

Asked by: Jeff T
Hi Jeff, Sorry no, this sensor does not allow for work hours/night control. For more advanced sensor timing control you might want to consider the DLM line of products where this is achievable.
Answered by: Tier 1 Tech Support
Date published: 2024-08-02

I’m having issues getting the DT-355 to function properly after installing a new DT-355. Can you explain the function of the (light level and the ultrasonic sensitivity) features?

Asked by: Ben19
Hi Ben, Please reach out to our tech. support team for further assistance with programming the DT-355 or refer to the resources section of each product for cut sheets and detailed instructions for activating or de-activating product features. Legrand Technical Support: Phone: 1 800-879-8585, Option 3 then Option 1 Mon - Fri: 7am - 7pm CST (excluding holidays)
Answered by: Tier 1 Tech Support
Date published: 2023-03-07

One of the answers to a question asked previously was that a DT-355 Line voltage sensor could be combined with a Radiant 0-10V dimmer on the load side. Is this correct? I am about to order this combination of devices and I want to make sure.

Asked by: John
Hello John, Yes, you can utilize a radiant 0-10v dimmer on the load side of the DT-355 sensor. Please feel free to give us a call if you would like to discuss this configuration further. legrand Contact information: Phone #: 844-957-3783 - Option 1, followed by option 2 for Technical Support. Monday - Friday | 8:00am - 6:00pm Eastern Standard Time (excluding holidays) Best Regards, Technical Support
Answered by: Justin
Date published: 2022-10-25

Can a dimmer switch be incorporated with the occupancy sensor to dim the lights when needed?

Asked by: Mike25
Yes, a line voltage switch/dimmer can be added to the load side of the DT-355.
Answered by: Tier 1 Tech Support
Date published: 2024-04-19

Do you have a sensor rated to 0F ?

Asked by: Anonymous
The CB-100 is a PIR only sensor, which can operated -40 to 95F. Please view attached SPEC sheet
Answered by: Tier 1 Tech Support
Date published: 2022-10-11

can these occupancy sensors be utilized in a cleanroom setting? specifically ISO 5-9 rated cleanrooms

Asked by: bdecker
No, our sensors are not cleanroom certified.
Answered by: Tier 1 Tech Support
Date published: 2022-06-01

What is the maximum distance the occupancy sensor can be from the ground for it to work properly

Asked by: Stephen M Ball
The DT-355 is designed for a ceiling heights of about 8-12 feet from the floor.
Answered by: Legrand Technical Support
Date published: 2022-10-11

Does this sensor cover minor motion? If so, what are the distances for that?

Asked by: JBJB
The DT-355 is a Dual-Technology sensor that has both PIR and Ultrasonic technology built in . The sensor is able to detect major and minor motion up to 1000 sqft when mounted below 10'.
Answered by: Tier 1 Tech Support
Date published: 2022-02-02

We have these thru out our warehouse, but would like the one by the entry door to stay on, is that possible?

Asked by: Anonymous
To override all sensor functions on the DT-355, set the Ultrasonic Sensitivity trimpot to the fully counterclockwise (Service) position. This bypasses the occupancy control functions of the sensor.
Answered by: Tier 1 Tech Support
Date published: 2024-11-12

Hello, is the DT-355 sensor rated for exhaust fans?

Asked by: KB311
No, the DT-355 has no rating for motor loads. I suggest looking at our BZ power packs and a 24v low voltage sensor. BZ power packs are rated for motor loads.
Answered by: Tier 1 Tech Support
Date published: 2023-06-08

Comparing with the other product Ultrasonic Ceiling Occupancy Sensor, 24VDC (W-500A), which sensors would be more suitable for a 150sq.m classroom? Comparing to its technologies, lifetime and price. Thank you.

Asked by: Nelson
Dual technology sensors are most commonly used in this application. They work using a combination of PIR and Ultrasonic technology. As individuals move throughout a given space, Ultrasonic wave analysis and the Doppler effect help detect indirect motion while passive infrared sensors monitor presence directly.
Answered by: Tier 1 Tech Support
Date published: 2021-07-26

we are looking for an occupancy sensor that will fit in a single gang electrical box. do you offer one?

Asked by: webb man
Good Afternoon, Thank you for contacting Wattstopper. We offer several sensor switch options that will fit in a single gang electrical box. Please go to our website www.legrand.us and you can search Wall Switch Sensors. We do not have an option that is a sensor only. The correct device for your situation will depend on your application and if you want a line voltage or low voltage sensor. Please let us know if we can offer any further assistance. Best Regards, Wattstopper Technical Support 800-879-8585
Answered by: Tier 1 Tech Support
Date published: 2021-07-20

Can you use two ceiling sensor in a large room ?

Asked by: SteveO
Yes, multiple ceiling sensors can be used to cover a large area.
Answered by: Legrand Technical Support
Date published: 2022-12-06
  • y_2025, m_4, d_22, h_6CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_2, bvpage2n
  • co_hasquestionsanswers, tq_22
  • loc_en_US, sid_DT-355, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_legrand
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 42ms
  • QUESTIONS, PRODUCT