text.skipToContent text.skipToNavigation

Dual Tech Occupancy Sensor, 24VDC, Center Mount, 360°, USA

DT-300-U Wattstopper
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getAggregateRating, 22ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

The DT-300 Series Dual Technology Ceiling Sensors combine the benefits of passive infrared (PIR) and ultrasonic technologies to detect occupancy. Sensors have a flat, unobtrusive appearance and provide 360 degrees of coverage.

BAA Yes
  • Send
  • Save as PDF
  • Add to favorites Remove from favorites

Features

  • Sensors work with low-voltage momentary switches to provide manual control
  • Patented ultrasonic diffusion technology spreads coverage to a wider area
  • LEDs indicate occupancy detection
  • Uses plug terminal wiring system for quick and easy
  • Eight occupancy logic options provide the ability to customize
  • Available with isolated relay for integration with BAS or HVAC
  • BAA/TAA-compliant models available

Specifications

General Info
Product Line Wattstopper
UPC Number 754182926800
Country Of Origin United States
Features Indicator Lights, IR (Infrared), Motion Sensor
Application Sector Commercial
Warranty Type 5-Year
Dimensions
Product Width US 4.5 in
Product Weight US 0.33 lb
Product Volume US 59.0 cu in
Product Depth US 2.1 in
Product Height US 4.5 in
Product Length US 4.5 in
Additional Information
Product Environmental Profile Yes
Technical Information
Sensor Type Occupancy
Amperage 43 A
Sensor Technology Passive Infrared (PIR), Ultrasonic
Indicator LED Light
Connection Type Wired

Resources

Reviews

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Questions & Answers

Can I use a 4 square box with a single gang mud ring to mount DT-300 ceiling sensors & LMDC-100 occupancy sensors?

Asked by: Jeff
An Octagonal J Box is recommended for the DT-300. A standard Single Gang box is appropriate for an LMDC-100. (Please note these 2 devices are not compatible with each other.)
Answered by: Tier 1 Tech Support
Date published: 2023-09-12

Is the DT-300 compatible with a BZ-250

Asked by: RValencia
Yes, the DT-300 is compatible with all of our BZ-series power packs
Answered by: Tier 1 Tech Support
Date published: 2023-07-10

I have an existing system with BT-150 power packs, DT-300 Ceiling Mount Occ Sensors, and LP8 Panel. I am looking to add dimming wall switches to this system. What part numbers do I need? Can this be a wireless switch programmed to the sensor?

Asked by: Dan
Hi Tier 1 Tech Support - thank you for responding. I mistakenly said dimming. I do not need dimming switches I am just hoping to find wireless switches so that i can program them to the existing DT-300 occ sensors without opening up walls/ceilings.
Answered by: Dan
Date published: 2023-06-29

I have a DT-305 and the two incandescent light fixtures that it controls are blinking on and off constantly. Is this a defective sensor or power pack issue?

Asked by: Bruce
Please reach out to our tech. support team for further assistance troubleshooting this issue. Legrand Technical Support: Phone: 1 800-879-8585, Option 3 then Option 1 Mon - Fri: 7am - 7pm CST (excluding holidays)
Answered by: Tier 1 Tech Support
Date published: 2023-03-27

is the DT 300 ceiling sensor compatible with the DT 305 ceiling sensor, to use in the same lighting system

Asked by: Scott
Hi Scott, Yes, these sensors can be hooked up in parallel to work together on the same system.
Answered by: Tier 1 Tech Support
Date published: 2023-03-07

Does the sensor provide data as to how often the area is occupied?

Asked by: Eric S
Hi Eric, Sorry but no the sensor does not provide that data with this model.
Answered by: Tier 1 Tech Support
Date published: 2023-01-10

CAN I PUT 2 DT-300 SENSORS ON 1 POWER PACK ?

Asked by: Anonymous
Yes, you can install up to 4 sensors on one power pack.
Answered by: Legrand Technical Support
Date published: 2022-12-06

Can a dimmer switch be used in conjunction with this occupancy sensor?

Asked by: Mike25
Yes, we have the DCLV2 0-10v wall dimmer which is also compatible with our BZ-series power packs
Answered by: Tier 1 Tech Support
Date published: 2022-07-06

I want to use the internal isolated (DT300) relay output 24VAC/Vto signal occupancy vs non-occupancy to my controller. however, the controller has 0-5, 0-10 VDC, 4-20mA, and dry contact inputs.please let me know how to match output to controller input?

Asked by: CuriousMatt
The isolated relay on the DT-300 is a dry contact which I would recommend you to use unless your controller need voltage. If you are needing more It would be best to contact Wattstopper Tech Support at 1-800-879-8585 option#1 for us to gather more information to help resolve your issue.
Answered by: Tier 1 Tech Support
Date published: 2022-06-06

CAN IT BE MOUNTED IN A WET LOCATION

Asked by: GARY
This sensor is designed to be installed indoors. It is not weather rated and the elements would damage the sensor. If you would like to discuss alternatives, please call 1-800-879-8585 Option 1 for Technical Support.
Answered by: Tier 1 Tech Support
Date published: 2022-05-31

Can the DT-300 sensor be wired to have sensor turns lights on and 0-10V dimmer switch controls light output?

Asked by: Anonymous
Hello Mark, The configuration you have requested is possible if the Sensor is wired to the 0-10v dimmer first, followed by the dimmer being wired to the light fixture driver. *A potential delay can occur with the lighting fixture turning on/off via this configuration. Please feel free to give us a call if you need further assistance. legrand Contact information: Phone #: 844-957-3783 - Option 1, followed by option 2 for Technical Support. Monday - Friday | 8:00am - 6:00pm Eastern Standard Time (excluding holidays) Best Regards, Technical Support
Answered by: Justin
Date published: 2022-05-23

is it possible to order the depluggable terminal and spring clips separately ?

Asked by: Anonymous
Hello, We unfortunately do not sell the depluggable terminal and spring clips separately at this time. Please feel free to give us a call if you need further assistance. legrand Contact information: Phone #: 844-957-3783 - Option 1, followed by option 2 for Technical Support. Monday - Friday | 8:00am - 6:00pm Eastern Standard Time (excluding holidays) Best Regards,
Answered by: Justin
Date published: 2022-03-18

Is the Wattstopper DT-300 listed by a National Recognized Testing Laboratory (NRTL), such as Underwriters Laboratories, Inc. (UL)?

Asked by: Drew
Yes, the DT-300 is UL listed.
Answered by: Tier 1 Tech Support
Date published: 2022-01-12

Can’t control two back pack with one sensor 

Asked by: Cuba
You should be able to have multiple powerpacks on one sensor using the attached wiring diagram.
Answered by: Legrand Technical Support
Date published: 2022-01-07

how do you install the product what are the steps to installing it

Asked by: Maglec Banewood
Here is a link to the complete set of installation instructions for the sensor. https://legrand.webdamdb.com/directdownload.php?ti=55647327&tok=pG2pR9JQX0RB5Rj0EAPWCgRR
Answered by: Legrand Technical Support
Date published: 2021-11-29

How many sensors can be put daisy chained together?

Asked by: Jgpiii
Each Wattstopper BZ series power pack can supply power for 7 DT-305 sensors.
Answered by: Tier 1 Tech Support
Date published: 2021-09-15

What is the recommended mounting height for the DT-300; 305; 355 ceiling sensors. Customer has 25' ceiling and I am not sure if these are rated for that height.

Asked by: JoJo
The sensor is design for mounting height of 8-12 feet.
Answered by: Legrand Technical Support
Date published: 2021-08-23
  • y_2024, m_10, d_7, h_4CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_2, bvpage2n
  • co_hasquestionsanswers, tq_25
  • loc_en_US, sid_DT-300-U, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_legrand
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 10ms
  • QUESTIONS, PRODUCT