PIR Ceiling Occupancy Sensor 2000 sq. ft. 24 VDC,
CX-100
Wattstopper
Bazaarvoice SAP Hybris Integration Version 2.8.1
Wattstopper’s CX-100 Series Passive Infrared (PIR) Ceiling/Wall Sensors detect occupancy to control lighting in a wide variety of applications. These sensors provide superior coverage and performance with great energy savings.
BAA
No
- No
- Yes
Footprint
2000 sq ft
- 50 linear ft
- 90 linear ft
- 120 linear ft
- 2000 sq ft
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Features
- Turns lights on and off based on occupancy
- User-adjustable time delay and sensitivity
- ASIC technology reduces components and provides greater reliability
- Choice of four coverage patterns
- Built-in light level sensor
- Isolated relay for use with HVAC or other control systems
- Automatic or manual-on operation when used with a BZ-150 Power Pack
Specifications
General Info
Color | White | ||
Product Series | CX-100 | ||
Type | Sensor | ||
Finish | Glossy | ||
Application Sector | Commercial | ||
Product Line | Wattstopper | ||
Country Of Origin | China | ||
Features | Adjustable Time Delay, Indicator Lights, Isolated Relay, Light Level Sensor, Power Pack Required, Sensitivity Adjustment, Wide Angle | ||
Included | J-Box Cover Plate, Sensor Mask, Swivel Bracket | ||
Installation Location | Ceiling, Wall | ||
Warranty Type | 5-Year | ||
Standard | UL, cUL, ISO 9002 | ||
UPC Number | 754182911264 |
Dimensions
Product Depth US | 3.3 in | ||
Product Height US | 3.4 in | ||
Product Volume US | 71.668 cu in | ||
Product Width US | 3.4 in | ||
Product Weight US | 0.3084 lb |
Additional Information
RoHS Compliant | Yes | This product meets the material restrictions of Article 4 of the RoHS Directive (2011/65/EU), including Commission Delegated Directive 2015/863. |
Technical Information
Current Draw | 19 mA | ||
Number of Rockers | 0 | ||
On Function | Auto On | ||
Wire Connection Type | Flying Leads | ||
Compatibility | BZ Power Packs | ||
Has Battery | No | ||
Indicator | PIR Detection LED | ||
Indoor/Outdoor | Indoor | ||
Input Voltage | 24 VDC/VAC | ||
Line Frequency | 60 Hz | ||
Load Rating | 1 A @ 24 VDC | ||
Mounting Type | J-Box, Surface, Swivel Bracket | ||
Number of Buttons | 0 | ||
Timer Type | DIP Switch | ||
Timer Duration | 15 Seconds, 2-30 Minutes | ||
Operating Temperature | 0°-55°C, 32°-131°F | ||
Operating Temperature Max | 131 °F | ||
Operating Temperature Min | 32 °F | ||
Operating Humidity | 5-95% RH (Non-Condensing) | ||
Sensing Range | 55 ft | ||
Sensor Type | Occupancy | ||
Sensor Technology | Passive Infrared (PIR) | ||
Sensor Coverage | 2000 sq ft | ||
Sensor Coverage Pattern | 180 ° | ||
Sensor Mounting Height | 10 ft | ||
Storage Temperature | 23° - 176° F, -5° - 80° C | ||
Engraving Type | Blank |
Resources
Cutsheet
Installation Instructions
CAD Drawings
Specifications
User Guides
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
Can these be safely used in exterior locations if mounted under soffit?
The CX-100 sensor does not have an IP rating suited for exterior usage
Date published: 2022-08-29