The FSP-201 mounts in an outdoor lighting fixture and provides multi-level control based on motion and/or daylight contribution. It controls 0-10 VDC dim-to-off LED drivers or ballasts, or works with a power pack to control other loads. When used with an FSP-Lx Lens, the sensor is rated for wet and cold locations. All control parameters are adjustable via a wireless configuration tool capable of storing and transmitting sensor profiles.

Voltage 120/277 VAC
  • Send
  • Save as PDF
  • Add to favorites"> Remove from favorites
    Add to favorites Remove from favorites

Features

  • Fully adjustable high and low dimmed light levels; optional dusk to dawn control
  • Controls 0-10V dim-to-off LED drivers or ballasts, or works with a power pack to control other loads
  • Hold off setpoint with automatic calibration option for convenience and added energy savings
  • Adjustable via handheld wireless configuration tool
  • IP66 rated with choice of lenses for wet and outdoor locations, and mounting heights from 8’ to 40’
  • Adjustable time delay and cut off delay

Specifications

General Info
Product Line Wattstopper
UPC Number 754182931231
Country Of Origin China
Dimensions
Product Width US 1.0 in
Product Weight US 0.17 lb
Product Volume US 13.32 cu in
Product Depth US 2.0 in
Product Height US 3.7 in
Additional Information
Product Environmental Profile Yes
Technical Information
Sensor Type Occupancy, Daylight

Reviews

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Questions & Answers

What is the default position for the FSP-211, if it were to fail at EOL? Would the light default on or off?

Asked by: Bwilliams
Whether it fails in the ON or OFF state depends entirely upon the mode of failure, so we cannot state that it will always fail in a particular state.
Answered by: Tier 1 Tech Support
Date published: 2022-11-11

when used with ELCU-200. when power is lost to FSP-211 or FSP-211B will the fixture go to 100% luminance? Does it matter if it is FSP-211 or FSP-211B?

Asked by: shane

what is the difference between FSP-211 and the FSP-211b

Asked by: shane
  • y_2024, m_3, d_4, h_8CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.38
  • cp_2, bvpage2n
  • co_hasquestionsanswers, tq_11
  • loc_en_US, sid_FSP-211, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_legrand
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 40ms
  • QUESTIONS, PRODUCT