DIGITAL WIRELESS CONFIGURATION TOOL w/USB
LMCT-100-2
Wattstopper
Bazaarvoice SAP Hybris Integration Version 2.8.1
The LMCT-100-2 Wireless Configuration Tool is a handheld tool for advanced remote configuration of any Wattstopper Digital Lighting Management (DLM) system. The tool enables system and device modifications via pushbutton, without ladders or tools, as well as easy duplication of settings between DLM local networks.
BAA
No
- No
- Yes
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Features
- Wireless advanced configuration capabilities for Digital Lighting Management systems
- Component of Digital Lighting Management integrated control systems
- Easy-to-read OLED screen
- Micro-USB port allows easy updating of firmware
- 2-way IR communication for data upload, download, confirmation and storage
- Easy-to-use navigation pad
- Configures occupancy sensors, switches, room controllers, photosensors and DLM relay panels
Specifications
General Info
| Color | Black | ||
| Product Series | LMCT | ||
| Type | Configuration Tool | ||
| Material | ABS | ||
| Application Sector | Commercial | ||
| Product Family / Series / Group | Digital Lighting Management | ||
| Product Line | Wattstopper | ||
| Country Of Origin | China | ||
| Included | Batteries, Carrying Case | ||
| Warranty Type | 5-Year | ||
| Standard | RoHS | ||
| UPC Number | 754182941766 |
Dimensions
| Product Depth US | 1.1 in | ||
| Product Height US | 4.0 in | ||
| Product Volume US | 36.06 cu in | ||
| Product Width US | 1.5 in | ||
| Product Weight US | 0.1 lb |
Additional Information
| Security | Yes | This product is ioXt certified | |
| RoHS Compliant | Yes | This product meets the material restrictions of Article 4 of the RoHS Directive (2011/65/EU), including Commission Delegated Directive 2015/863. |
Technical Information
| Battery | 3 AAA Batteries | ||
| Compatibility | DLM Wired | ||
| Indoor/Outdoor | Indoor | ||
| Engraving Type | Icon | ||
| Wireless Range | IR, up to 32 ft |
Resources
Installation Instructions
CAD Drawings
Supporting Document
User Guides
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
hello, I have a LMCT that has a screen that flashes on and off, It has new batteries but It has been a year since we last used it. How do I repair it?
Wattstopper does not have a recommendation to repair the LMCT. If replacing the batteries and resetting the LMCT does not correct the issue, we suggest replacing it.
Date published: 2024-07-09
We are looking for the windows device driver for windows to recognized the device. Can you help point us in the correct location?
To update the LMCT-100-2 firmware on a Windows PC, ensure you have:
-A USB to micro-USB cable for charging and data transfer.
-A Windows-operated PC.
-STM Cube Programmer from STMicroelectronics (for Windows 11). If you encounter errors, use the DfuSE Demo Software instead.
-The firmware file for the LMCT-100-2.
The device driver should automatically install from the Windows Driver Database when connected to your PC. If issues arise with STM Cube Programmer, the DfuSE Demo Software is a recommended alternative.
Date published: 2024-03-28
I need to update the firmware on a LMCT-100-2. Instructions say to use DfuSe Demo software. Where do I download that from?
Due to the complexity of updating the firmware of LMCT-100-2, we recommend contacting Technical Support, using 1-800-879-8585 option 3 then option 1, to discuss the process and obtain the current firmware file.
Date published: 2025-09-12
Will thisbdevice work in place of the fsir 100 ?
No, the LMCT-100-2 is used to configure DLM systems.
The FSIR-100 is used to configure FSP-2x1 Fixture Sensors.
Date published: 2023-12-06
how do i set a ceiling dual sensor to where its always on ? i thought you would change the time delay to override but when i do that it wont save the setting, only lets me goto 30min on the delay.
There are two ways that you can set the sensor so that it won't turn the lights off.
1. Set the sensitivity to 'Override', and SEND the change to the sensor (note: SAVE simply saves the change to the LMCT-100-2 configuration tool, but does not send it to the sensor).
2. Unbind the sensor from the load(s) you no longer wish for it to control.
Date published: 2023-12-06
As Uaual I am unable to connect with the software DefuSE software there is no info on how to use th BIM Model ifo provided
Using the DfuSe Demo software, appropriate firmware, and a micro-USB cable, a user can update the firmware in the v2 (HW-6) LMCT -100.
Be sure your micro USB cable has the data pair in it and is not simply a charging cable. If the update process is followed and the app does not display choices in the "Available DFU Devices" drop-down, the cable is the most likely cause.
Date published: 2023-09-11
Will the LMCT-100-2 program the LMDC-100 ceiling mount sensors and LMDM-101 light switches?
Yes, you can use the LMCT to program all wired DLM sensors and switches.
Date published: 2023-09-06
I have a LMCT-100 which has HW=5 and Version FW=5.24. What are my options for up grades, does not have a USB plug?
Hi Barry,
Sorry, that LMCT-100 has been discontinued and replaced with the upgradable LMCT-100-2. If the remote does not have the USB port in the battery compartment, then no upgrade is available.
Date published: 2024-07-07
How to update firmware. Getting message driver is unavailable . STM32 BOOTLOADER driver is unavailable. How can I fix this .
Please reach out to our tech. support team for further assistance with upgrading the LMCT-100.
Legrand Technical Support:
Phone: 1800-879-8585, Option 1
Mon - Fri: 7am - 7pm CST (excluding holidays)
Date published: 2023-04-06
Trying to upgrade LMCT-100-2 from version 6.14 to current 6.29 Made it to the point where the file to upgrade is selected and the program says the file is in the incorrect format. It doesn't like the .hex file. How is it uploaded?
There is a problem with that HEX file and cannot be upgrade to the LMCT-100-2.
A very lazy company!!!!
https://legrand.webdamdb.com/directdownload.php?ti=44269428&tok=Ma3CbkORPkhMgEve/B9WyQRR
Date published: 2023-04-06
What is the toggleNT mode?
ToggleNT is short for Toggle Non- Tracking
By default, when the Type is Group, the Mode is set to
ToggleNT. With this value, the button will toggle, but the LED will
not track the actual settings of the loads. Additionally, the button
will not track if another source such as a sensor turns the load
ON. The reason for this is that the button can’t track the status of
all loads in the group.
Date published: 2023-04-06
Why will the system not go into plug n go
There are a variety of reasons why a DLM system does not go into plug n go. There may be wiring issues or the controller may need to be reset. Please contact Wattstopper Technical Support for more info @ 800-879-8585.
Date published: 2023-04-06
is the LMCT-100-2 with firmware 6.14 compatible with WS-FSP-221B
No, you will need a FSIR-100 remote to program FSP- 2X1 sensors.
Date published: 2023-04-06
I am looking for all the button feature on LMCT 100-2
The full LMCT-100-2 User Guide is available on our website at:
https://www.legrand.us/lighting-controls-and-systems/digital-lighting-management/software-and-configuration-tools/digital-commissioning-tool-w-usb/p/lmct-100-2.
If you have any issues accessing this link, please contact Technical Support at 800-879-8585.
Date published: 2023-04-06
How do you reset a LMRC-213 back to factory plug n go setting.
There are 2 ways to reset the LMRC-213. The first is using the LMCT-100-2 go to Utilities > Force System Into PNG. It will ask are you sure? Press select again and the LMRC as well as other attached DLM products will be set back to factory PNG settings. The second method is to hold the configure button on the LMRC (or other attached DLM devices) for 5 seconds. When the red LED flashes rapidly hold the button for 20 seconds letting go when the LED begins to flash again.
Date published: 2023-04-06
Bazaarvoice SAP Hybris Integration Version 2.8.1