Wiremold ALA4800 Series Dual Compartment Raceway Base
ALA4800B-10
Wiremold
Bazaarvoice SAP Hybris Integration Version 2.8.1
The Wiremold ALA4800 Aluminum Raceway System meets the demands of commercial spaces, providing a handsome and effective method of consolidating power and communications cabling. In laboratories, healthcare facilities and upscale office locations, the two channel, two cover aluminum raceway directs power and communication cabling services where required and provides access to one channel at a time.
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Specifications
General Info
Product Line | Wiremold | ||
Color | Silver | ||
UPC Number | 786776189667 | ||
Country Of Origin | Mexico | ||
Application Sector | Commercial | ||
Standard | cULus Listed Surface Metal Raceway: File E4376: Guide RJBT/RJBT7 | ||
Type | Raceway |
Dimensions
Product Width US | 120.0 in | ||
Product Weight US | 46.28 lb | ||
Product Volume US | 1533.6 cu in | ||
Product Depth US | 2.13 in | ||
Product Height US | 6.0 in |
Additional Information
RoHS Conformant | Yes | This product meets the material restrictions of Article 4 of the RoHS Directive (2011/65/EU), including Commission Delegated Directive 2015/863. | |
Product Environmental Profile | Yes |
Listing Agencies / 3rd Party Agencies
cULus ListingNumber | E4376 | ||
cULus Listed | Yes |
Buy American Act Compliance
NAFTA | Yes |
Technical Information
Voltage | 600.0 V |
Resources
Installation Instructions
BIM Models
Product Environmental Profile
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
What keystone plate/insert options do you have for 2port Leviton QuickPort jacks in ALA4800 raceway? Do you have any front load options?
Hello Roy,
Two Leviton jacks can be installed in ALA4800 using a combination of device plate ALA-2A and CM2-U2KEYA-GY.
Listed below are links to the cutsheets for the items mentioned above.
https://legrand.webdamdb.com/directdownload.php?ti=55656644&tok=yICJJ25MCQFCDkWSDco4GQRR
https://legrand.webdamdb.com/directdownload.php?ti=55653271&tok=6sp0ZBsiLmjYiD5H7ifgVARR
Thank you!
Date published: 2022-10-14
Hi! Can you provide a detail or explanation of how to pass through a perpendicular wall from raceway to raceway. I have a long length of raceway with an obstructing wall i need to pass through. Do I need to convert to conduit to make the passage?
Hello Mike,
The NEC permits surface metallic raceway to pass through walls with the following requirements;
Article 386.10(4) under Uses Permitted. Extensions through walls and floors. Surface metal raceway shall be permitted to pass transversely through dry walls, dry partitions, and dry floors if the length passing through is unbroken.
As long as the installation meets the two requirements above, (1) the length passing through the wall is unbroken and (2) access to the conductors is maintained on both sides of the wall.
Thank you,
Date published: 2022-08-26
Do you still make the Aluminum 3000 series? or AL4000 series. And cover plates that fit, example AL3046D
Good Afternoon-
Yes, we do still offer the AL3000 series raceway. These are offered as a prewired raceway through our Project Services team. You can contact them by email: Wiremold.projectMgmt@legrand.us
Date published: 2022-07-05
Bazaarvoice SAP Hybris Integration Version 2.8.1