50 Amp 125/250V NEMA 14-50R Flush Mount Electrical Outlet for Ranges / Dryers
3894
Pass and Seymour
50 Amp 125/250V NEMA 14-50R Flush Mount Electrical Outlet for Ranges / Dryers is rated
out of
5 by
2.
Bazaarvoice SAP Hybris Integration Version 2.8.1
$57.99 USD
A durable solution that provides 50A 125/250V NEMA 14-50R power access for ranges and dryers. A single, flush-mount, straight-blade receptacle. 3-Pole, 4-Wire
Quantity
In Stock
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Specifications
General Info
Product Line | Pass & Seymour | ||
Country Of Origin | China | ||
UPC Number | 785007807905 |
Dimensions
Product Depth US | 2.2 in | ||
Product Width US | 2.5 in |
Listing Agencies / 3rd Party Agencies
CSA Listed | Yes | ||
cULus Listed | Yes |
Technical Information
Amperage | 50 A |
Resources
Cutsheet
Specifications
Reviews
Rated 5 out of
5
by
Doc from
Great EV charger outlet
Well built outlet to support EV charging safely and reliably
Date published: 2023-11-10
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
Is this rated for use with EV chargers?
Can you use a 60AMP Circuit breaker on this 50AMP outlet?
Date published: 2024-07-18
Was this tested for #4 AWG Copper? #4 AWG Copper fits and I’m trying to see if this was tested for #4 WG Copper.
Hello,
The 3894 is rated for #10 - #6 AWG Size.
Best Regards,
Technical Support
Date published: 2024-08-05
I have #4 AWG Copper Wire at the location that I would like to install this. It’s connected to a 50A Breaker. Will this product accommodate #4 AWG Copper Wire and fit into the lugs / connection point properly?
Unfortunately no, this receptacle is rated for #10 – #6 AWG.
Date published: 2024-07-07
Torque specs for tightening terminals
Hello Greg,
3894 Torque specs for terminals is 14 in/lb.
Best Regards,
Technical Support
Date published: 2024-06-22
What is the box fill for the 3894
Per NEC 314.16(B)(4) For each yoke or strap containing one or more devices or equipment, a double volume allowance in accordance with Table 314.16(B) shall be made for each yoke or strap based on the largest conductor connected to the device(s) or equipment supported by that yoke or strap.
Lets assume you are using 6AWG wire (good for 55 amps at 60C) the table requires 5 cubic inches for each 6 AWG conductor.
Since a device requires a double allowance in this scenario the device would require a deduction of 10 cubic inches.
The rest of the deductions would be determined by how the device is wired. The number of conductors, clamps, grounding conductors used in the installation would need to be known.
Please note that the size of the deduction for the device is based on the wire size. So, if you are using a higher rated wire (75C or 90C) for the installation the overall size of the deduction for the device would decrease.
Date published: 2022-07-19
What is the operating temperature range of this outlet? As is, what is the maximum temperature and minimum temperature that this outlet will still perform? (ex., installed in a garage, this outlet will need to function in both winter and summer weather)
Environmental Ratings:
Operating Temperature: Maximum continuous +75°C, minimum -40°C without impact
Date published: 2022-07-16
what is the operating temperature rage of this outlet?
The 3894 receptacle is rated for use with 75°C wire.
Date published: 2023-02-17
Is there any similar product but 208 V?
Our 3870 Power Outlet is 60A, 120/208V rated:
https://www.legrand.us/passandseymour/range-dryer/flush-mount/60a/3870.aspx
Date published: 2020-05-04
Can this be adapted to a standard 4 prong dryer outlet?
The 3894 is already a 4 wire dryer outlet so I would contact Technical Support so we can understand your inquiry better.
Pass & Seymour products
1.800.223-4185 opt 1
Mon - Fri: 8am - 8pm EST
(excluding holidays)
Email Us - tech.support@legrand.us
Date published: 2020-02-25
Are the terminals on this device rated for use with aluminum wire?
The 50A Power Oulet is rated for #10 – #6 AWG Copper/Copper-clad/Aluminum wire.
Date published: 2019-12-09
What is the rating of the 3894 receptacle to ground?
The 3894 Power Outlet is a 50A 125/250V rated receptacle.
Date published: 2022-07-16
This is the cross reference to the cooper 5754N which is much more expensive and I need it to be a high quality industrial grade receptacle due to the application, so my question, is the 3894 high quality industrial grade receptacle like the 5754N?
Yes, it is of the same quality.
Date published: 2019-11-07
What is the right wallplate ss for this outlet(3894)? Thanks
Thank you for your question regarding Pass & Seymour Power Outlet(Model # 3894).
The single gang wallplate for this outlet is SS724 and two gang is SS702.
Date published: 2022-07-16
Pertaining to your cat. no. 3894 which is a parallal blade, 50amp, 3 pole, 4 wire. Is this receptacle a grounding type? Is the center circle for a grounding plug? What is the NEMA configuration designation?
Thank you for your inquiry regarding our 3894 receptacle. This product is grounding; the top U-shaped pin is for the ground wire. The NEMA configuration for this receptacle is 14-50R. Hope this helps!
Date published: 2022-03-07
A lot of "standard" 14-50 outlets have been burning up when used for EV's. They're finding they aren't really rated for the EV loads and constant plugging in. Some mnftr's came out with a beefier EV rated one. Is the 14-50WR version truly EV rated?
I see the 3894 is good to use with #6-#10 wire. the 3894WR is good for #3 to #10. why the difference? do you offer the regular 3894 with higher wire rating?