Wood and Steel Stud Bracket Box with Quick/Click
S235S50AC
Pass and Seymour
Bazaarvoice SAP Hybris Integration Version 2.8.1
Double Gang, Wood and Steel Stud Bracket Box with Quick/Click, 3/8-inch offset for wood and steel stud mounting. Four Auto/Clamps on each end. For use with 3/8-inch to 5/8-inch wallboard. 50 pack.
- Send
- Save as PDF
-
FavoriteAdded to Favorites Go to favoritesRemove from favorites?
Features
- Available in single, two, three, four gang and 4 inch square boxes.
- Two, three and four gang boxes and 4 inch square include exclusive Auto/Clamp feature.
- Single gang include Quick/Entry feature.
- Quick/Click feature offers fast and dependable installation of devices (single, two, three, and four gang).
- Unique offset tab assures proper alignment to wall face.
- Available with 3/8 inch offsets.
- Can be used for steel, aluminum, or wooden studs.
- Can be installed on steel studs with most standard crimping tools in addition to CT1 Crimping Tool.
- Molded of high-impact thermoplastic.
Specifications
General Info
Product Line | Pass & Seymour | ||
Color | Gray | ||
UPC Number | 785007207354 | ||
Country Of Origin | United States | ||
Application Sector | Residential/Commercial | ||
Standard | UL listed |
Dimensions
Cubic Capacity | 35 cu in |
Additional Information
Product Environmental Profile | Yes |
Technical Information
Number of Outlets | 2 |
Resources
Cutsheet
Installation Instructions
Brochure
Product Environmental Profile
Guide Form Specifications
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
Your multi gang plastic boxes that come stamped with a wire volume and corresponding conductor count. Do the volume and/or wire count account for the integral clamps? or does the installer have to account for them in their box fill calculation?
Clamp Fill. Where one or more internal cable clamps, whether factory or field supplied, are present in the box, a single volume allowance in accordance with Table 314.16(B) shall be made based on the largest conductor present in the box. No allowance shall be required for a cable connector with its clamping mechanism outside the box.
A clamp assembly that incorporates a cable termination for the cable conductors shall be listed and marked for use with specific nonmetallic boxes. Conductors that originate within the clamp assembly shall be included in conductor fill calculations covered in 314.16(B)(1) as though they entered from
outside the box. The clamp assembly shall not require a fill allowance, but the volume of the portion of the assembly that remains within the box after installation shall be excluded from the box volume as marked in 314.16(A)(2).
Date published: 2019-12-02