30A Non-NEMA Single Receptacle
3430
Pass and Seymour
Bazaarvoice SAP Hybris Integration Version 2.8.1
Receptacle Single 30A 120/208V 3-Phase-y
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Features
- Compact, impact-resistant nylon face and body are ultrasonically welded together for unrivaled strength.
- Face color coding by voltage facilitates locating and mating of proper devices.
- One piece, high-grade brass contacts offer excellent conductivity and heat-rise resistance.
- Clearly marked NEMA configuration, rating, and third-party listing on each unit's face.
- Single-piece, solid brass mounting strap is free of easily loosened rivets found on other brands.
- Side and external screw-pressure-plate back wire capability.
- Accepts #14 - #10 AWG.
Specifications
General Info
| Product Type | Receptacle | ||
| Application Sector | Industrial | ||
| Product Line | Pass & Seymour | ||
| Country Of Origin | Mexico | ||
| Features | Brass Mounting Strap, Impact Resistant | ||
| Wall Plate Included | No | ||
| Number of Receptacles | 1 | ||
| Outlet Type | Locking | ||
| Warranty Type | 1-Year Limited Warranty | ||
| Standard | UL498 | ||
| UPC Number | 785007343007 |
Dimensions
| Product Depth US | 1.2 in | ||
| Product Height US | 2.25 in | ||
| Product Width US | 1.437 in |
Listing Agencies / 3rd Party Agencies
| cULus ListingNumber | 140596 | ||
| cULus Listed | Yes |
Technical Information
| Amperage | 30 A | ||
| Connection Location | Back and Side | ||
| Wire Connection Type | Screw Terminals | ||
| Environmental Conditions | Consult the Factory | ||
| Indoor/Outdoor | Indoor | ||
| Number of Poles | 3-Way | ||
| Number of Wires | 4 | ||
| Phase | Three | ||
| Voltage | 120/208 V | ||
| Wire Size | 14 - 10 AWG |
Resources
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
I am hooking up # 8 wire ,ground,red,white,and black ,ground goes on G,white on W,red andblack on hot ,Right
The 3430 terminals are marked and should be wired as follows:
G - Ground, W - Neutral, X - Hot, and Y - Hot
Date published: 2019-10-30
Bazaarvoice SAP Hybris Integration Version 2.8.1
Recently Viewed
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
V511 | Wiremold
Add or extend power, phone, or data lines.
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
WS-301-347-R | Wattstopper
The WS-301 Passive Infrared (PIR) Wall Switch Sensor turns lighting or fan loads on and off based on occupancy and ambient light level.
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
CA18G | Pass and Seymour
Cast Weatherproof 2 Gang Cover
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
INFC04U-M4-E | Ortronics
4U Infinium High Density (HD) Enhanced Fiber Enclosure M4 Drawer Face