Features
- Compact, impact-resistant nylon face and body are ultrasonically welded together for unrivaled strength.
 - Face color coding by voltage facilitates locating and mating of proper devices.
 - One piece, high-grade brass contacts offer excellent conductivity and heat-rise resistance.
 - Clearly marked NEMA configuration, rating, and third-party listing on each unit's face.
 - Single-piece, solid brass mounting strap is free of easily loosened rivets found on other brands.
 - Side and external screw-pressure-plate back wire capability.
 - Accepts #14 - #10 AWG.
 
Specifications
General Info
                | Application Sector | Industrial | ||
| Product Line | Pass & Seymour | ||
| Country Of Origin | Mexico | ||
| Features | Brass Mounting Strap, Impact Resistant | ||
| Wall Plate Included | No | ||
| Number of Receptacles | 1 | ||
| Outlet Type | Locking | ||
| Warranty Type | 1-Year Limited Warranty | ||
| Standard | UL498 | ||
| UPC Number | 785007343007 | 
Dimensions
                | Product Depth US | 1.2 in | ||
| Product Height US | 2.25 in | ||
| Product Width US | 1.437 in | 
Listing Agencies / 3rd Party Agencies
                | cULus ListingNumber | 140596 | ||
| cULus Listed | Yes | 
Technical Information
                | Amperage | 30 A | ||
| Connection Location | Back and Side | ||
| Wire Connection Type | Screw Terminals | ||
| Environmental Conditions | Consult the Factory | ||
| Indoor/Outdoor | Indoor | ||
| Number of Poles | 3-Way | ||
| Number of Wires | 4 | ||
| Phase | Three | ||
| Voltage | 120/208 V | ||
| Wire Size | 14 - 10 AWG | 
Resources
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
I am hooking up # 8 wire ,ground,red,white,and black ,ground goes on G,white on W,red andblack on hot ,Right
            The 3430 terminals are marked and should be wired as follows:
G - Ground, W - Neutral, X - Hot, and Y - Hot
            
            
    Date published: 2019-10-30
        Bazaarvoice SAP Hybris Integration Version 2.8.1
Recently Viewed
            Added to Favorites
            Go to favorites
        
        
            Remove from favorites?
            
            
        
        
            Something went wrong. Please try again later.
            
        
    L1630FI | Pass and Seymour
                        30A NEMA L1630 Flanged Inlet
                        
                        
            Added to Favorites
            Go to favorites
        
        
            Remove from favorites?
            
            
        
        
            Something went wrong. Please try again later.
            
        
    L1230C | Pass and Seymour
                        30A NEMA L1230 Connector - Black Back Front Body
                        
                        
            Added to Favorites
            Go to favorites
        
        
            Remove from favorites?
            
            
        
        
            Something went wrong. Please try again later.
            
        
    L2330C | Pass and Seymour
                        30A L2330 Connector - Black Back Front Body
                        
                        