50A 480V California Standard Single Receptacle, 3-Pole 4-Wire, Black
CS8169
Pass and Seymour
Bazaarvoice SAP Hybris Integration Version 2.8.1
Receptacle California Standard Style 50A 3-Phase 480V Turnlok Registered
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Specifications
General Info
| Color | Black | ||
| Finish | Matte | ||
| Application Sector | Industrial | ||
| Product Line | Pass & Seymour | ||
| Country Of Origin | Mexico | ||
| Standard | UL 498 | ||
| UPC Number | 785007816907 |
Dimensions
| Product Depth US | 1.08 in | ||
| Product Height US | 3.28 in | ||
| Product Width US | 1.98 in |
Listing Agencies / 3rd Party Agencies
| CSA Listed | Yes | ||
| CSA File Number | 140596 |
Technical Information
| Amperage | 50 A | ||
| Number of Poles | 3-Way | ||
| Number of Wires | 4 | ||
| Phase | Three | ||
| Wire Size | 18 - 0 AWG |
Resources
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
What is the recommended metal cover plate for a 4-11/16 box or 4 square box? I've tried the RACO 878 and the mounting holes do not align?
Thank you for your inquiry. Pass & Seymour offers a Weatherproof (1-gang) cover for our 50 Amp locking receptacles.
Note: Part number CS8169 has a diameter of 1.98"
Date published: 2024-10-17
Customer states that their existing Hubbell CS8169 male plugs will not mate with my supplied P&S CS8169 Receptacle.
Hello Andrew, I'm sorry to hear you're having some trouble with your product, please contact P&S Technical Support via phone so we can troubleshoot with you. 844-957-3783
Date published: 2023-01-20
What do this outlet use ? THK
If you're asking what wire to use with the receptacle:
Terminal Accommodation #10 AWG min. – #6 AWG max
Date published: 2020-12-16
do you make this to fit a 2 gang box?
Thank you for your inquiry regarding our California Standard 50amp 3phase 480volt Turnlok (CS8169). We only make this product for a 1 gang box. You can put two of these in a 2 gang box but we do not have a single turnlok that takes up both gang openings. Hope this helps!
Date published: 2018-04-11
Bazaarvoice SAP Hybris Integration Version 2.8.1
Recently Viewed
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
CF54/200WH | Cablofil
Cablofil Industry leading powder coat wire mesh tray is your cost effective solution for data installations
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
AFGF153TRBK | radiant Collection
AFCI/GFCI Technology protect against electrical fires caused by arc faults and injury due to shock