Emergency Lighting Control Unit
ELCU-100
Wattstopper
Bazaarvoice SAP Hybris Integration Version 2.8.1
Wattstopper's Emergency Lighting Control Unit (ELCU) is a self-contained, emergency lighting control device. The ELCU provides all required functionality to allow any standard lighting control device to control emergency lighting in conjunction with normal lighting in any area within a building.
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Features
- Guarantees emergency lighting remains ON or is turned on when power to the control device is lost
- ““Watchdog”” feature allows emergency loads to be controlled in tandem with normal power loads
- Interfaces with fire alarm panel or security system
- Integrated push-to-test button
- UL listed for use in emergency circuits
Specifications
General Info
| Color | Red, White | ||
| Product Series | ELCU | ||
| Type | Emergency Load Controller | ||
| Material | ABS | ||
| Application Sector | Commercial | ||
| Product Line | Wattstopper | ||
| Country Of Origin | China | ||
| Installation Location | Enclosure | ||
| Warranty Type | 5-Year | ||
| Standard | UL 924, NEC, OSHA, NFPA 101 | ||
| UPC Number | 754182918546 |
Dimensions
| Product Depth US | 2.8 in | ||
| Product Height US | 3.4 in | ||
| Product Volume US | 51.282 cu in | ||
| Product Width US | 2.8 in | ||
| Product Weight US | 0.3513 lb |
Additional Information
| RoHS Compliant | Yes | This product meets the material restrictions of Article 4 of the RoHS Directive (2011/65/EU), including Commission Delegated Directive 2015/863. |
Technical Information
| Wire Connection Type | Terminal Block | ||
| Compatibility | EMTS-100 | ||
| Contact Configuration | 2-wire Momentary, N-C | ||
| Contact Rating | 24 VDC | ||
| Indoor/Outdoor | Indoor | ||
| Input Voltage | 120/277 VAC | ||
| Line Frequency | 50 Hz, 60 Hz | ||
| Load Rating | 10 A @ 120 VAC, 20 A @ 277 VAC | ||
| Location Rating | Dry | ||
| Mounting Type | DIN Rail | ||
| Number of Relays | 0 | ||
| Operating Temperature | 32°-131°F | ||
| Operating Temperature Max | 131 °F | ||
| Operating Temperature Min | 32 °F | ||
| Operating Humidity | 5-95% RH (Non-Condensing) | ||
| Storage Temperature | 23° - 176° F |
Resources
Installation Instructions
CAD Drawings
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
I am looking for two relay outputs solution with two switch-in lines for two emergency loads.
The ELCU is a single relay unit. To control two circuits, you would need to use two ELCUs.
Date published: 2024-03-28
Bazaarvoice SAP Hybris Integration Version 2.8.1
Recently Viewed
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
FP14SR-AWNM | Vantage
SoftLine provides a consistent aesthetic across our keypads. It is the perfect choice for a traditional design style available in 1-4 gangs.
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
LMDL-600-RPM | Wattstopper
The LMDL-600 is a wireless open loop photo sensor that measures the daylight contribution in order to automatically switch or dim multiple zones of lighting.
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
P820127HB | Ortronics
Straight Clamp Kit, 45 Deg, Two Straight Clamps
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
EN-M-DALI2-X | Wattstopper
The Wattstopper PLUS Wired Manager - DALI provides individual control of lighting, allowing you to schedule, allocate, and manage light in a resource-efficient and practical way
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
WP1014BKV1 | On-Q
Cable Access Strap
$14.21
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
3050 | Pass and Seymour
Single Gang Clamp Style, Standard Depth