Discontinued - PIR Ceiling Occupancy Sensor 1, 200 sq. ft. 24 VDC,
CI-205
Wattstopper
Bazaarvoice SAP Hybris Integration Version 2.8.1
Replaced by CI-305
Wattstopper's CI-200 Series Passive Infrared (PIR) Ceiling Sensors provide 360° coverage to detect occupancy in the controlled area. These low-profile sensors reliably control lighting in a variety of applications.
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Specifications
General Info
| Product Line | Wattstopper | ||
| Country Of Origin | China | ||
| Replaced by Part Number | CI-305 | ||
| UPC Number | 754182913305 |
Dimensions
| Product Depth US | 3.75 in | ||
| Product Height US | 2.75 in | ||
| Product Volume US | 38.67 cu in | ||
| Product Width US | 3.0 in | ||
| Product Weight US | 0.35 lb |
Additional Information
| DesignLights Consortium Qualified System | Yes | ||
| Security | Yes | This product is ioXt certified | |
| RoHS Compliant | Yes | This product meets the material restrictions of Article 4 of the RoHS Directive (2011/65/EU), including Commission Delegated Directive 2015/863. |
Technical Information
| Sensor Type | Occupancy | ||
| Sensor Technology | Passive Infrared (PIR) |
Resources
Instruction Sheet
CAD Drawings
57-003-1 - Any 8-Wire Occupancy Sensor "Standard Schematic"
dxf
57-003-1 - Any 8-Wire Occupancy Sensor "Standard Schematic"
pdf
57-003-1 - Any 8-Wire Occupancy Sensor "Standard Schematic"
png
57-003-1 - Any 8-Wire Occupancy Sensor "Standard Schematic"
dwg
57-003-1 - Any 8-Wire Occupancy Sensor "Standard Schematic"
pdf
57-010 - Multiple Occupancy Sensors Using One Power Pack
dxf
57-010 - Multiple Occupancy Sensors Using One Power Pack
png
57-010 - Multiple Occupancy Sensors Using One Power Pack
dwg
57-010 - Multiple Occupancy Sensors Using One Power Pack
pdf
57-039-11 - MB-1 Mounting Information using CI-Series Sensors
png
57-039-11 - MB-1 Mounting Information using CI-Series Sensors
dxf
57-039-11 - MB-1 Mounting Information using CI-Series Sensors
dwg
57-039-2 - CI Series Sensor Installation
dwg
57-039-2 - CI Series Sensor Installation
dxf
57-039-2 - CI Series Sensor Installation
pdf
57-039-2 - CI Series Sensor Installation
png
57-041-1 - 8-Wire Sensor Interfacing With A Thermostat
dxf
57-041-1 - 8-Wire Sensor Interfacing With A Thermostat
dwg
57-041-1 - 8-Wire Sensor Interfacing With A Thermostat
pdf
57-303 - CI, DT, UT-305 Standard Schematic
png
57-303 - CI, DT, UT-305 Standard Schematic
pdf
57-303 - CI, DT, UT-305 Standard Schematic
dxf
57-303 - CI, DT, UT-305 Standard Schematic
dwg
60-601-2 - LI/LP Relay Panels Occupancy Sensor Connection
dxf
60-601-2 - LI/LP Relay Panels Occupancy Sensor Connection
dwg
60-601-2 - LI/LP Relay Panels Occupancy Sensor Connection
pdf
CI-200-1
png
CI-200-1
dwg
CI-200-1
dxf
CI-200-1cp - CI-200-1 Coverage Pattern
png
CI-200-1cp - CI-200-1 Coverage Pattern
dwg
CI-200-1cp - CI-200-1 Coverage Pattern
dxf
CI-200
dwg
CI-200
dxf
CI-200
png
CI-200cp - CI-200 Coverage Pattern
dxf
CI-200cp - CI-200 Coverage Pattern
png
CI-200cp - CI-200 Coverage Pattern
dwg
CI-205-1
png
CI-205-1
dxf
CI-205-1
dwg
CI-205
png
CI-205
dwg
CI-205
dxf
57-041-1 - 8-Wire Sensor Interfacing With A Thermostat
png
60-601-2 - LI/LP Relay Panels Occupancy Sensor Connection
png
View More
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
I have a ci 200 series installed in some massage rooms. They are at max setting of 30 minutes and the lights are coming on halfway through a 1 hour session. Is there a solution for this?
Please reach out to our tech. support team for further assistance with over-riding this sensor.
Legrand Technical Support:
Phone: 1 800-879-8585, Option 3 then Option 1
Mon - Fri: 7am - 7pm CST (excluding holidays)
Date published: 2023-03-07
If I set the dip switch 6 to on/enable override, Does the sensor still do auto off or will the sensor be manual on/manual off?
setting DIP switch #6 to bypass will override all the sensor’s occupancy control functions. Lights can still be manually on/off controlled with a light switch.
Date published: 2023-12-15
Lights cycle on and off , been install for 10 years , just start this issue, power supply BZ-50 or sensor CI-205 problem? Are sensor W-500A and W-1000A obsolete ? if so what Replacement recommend ?
Most likely the power pack is the cause.
W500A DISC REC SUB UT3051
W1000A DISC REC SUB UT3052
Date published: 2022-10-24
I would like to completely disable the sensor. How can I do this?
Place all of the dip switches in the On position except for number 6, it will remain Off. This will place the sensor into Service mode.
Date published: 2025-10-24
Bazaarvoice SAP Hybris Integration Version 2.8.1
Recently Viewed
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
885I | radiant Collection
Sleek duplex outlet, perfect for upgrading standard power access with classic style.
$3.03
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
THRDPT | Cablofil
Plastic threaded rod protector can be used with any size of threaded rod
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
UDO12KITWH | Cablofil
Universal Dropout Kit- side mount 12" cable dropout in white.
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
AD2WP-TM | adorne Collection
Glossed to perfection, this wall plate adds the right amount of shine to any project or remodel. For use with adorne Furniture Power only.
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
TM870CC10 | radiant Collection
Sleek, easy-to-install 15A single-pole switch.
$4.45
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
CG4047WX | Wiremold
The work horse of surface raceway systems.