Switch and Outlet Box
S122R
Pass and Seymour
Single-Gang Deep Switch and Outlet Box, 100-Pack is rated
out of
5 by
1.
Bazaarvoice SAP Hybris Integration Version 2.8.1
Single-gang, deep switch and outlet box. Durable, impact-resistant thermoplastic boxes contain innovative extras that cut installation time. Extra deep for dimmers, GFCIs and thermostats, yet suitable for 2x4 construction. Provides two quick click entries. Qty 100.
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Specifications
General Info
Product Line | Pass & Seymour | ||
Color | Gray | ||
UPC Number | 785007207194 | ||
Country Of Origin | United States | ||
Construction | Thermoplastic | ||
Standard | UL Listed |
Dimensions
Cubic Capacity | 22 cu in |
Additional Information
RoHS Conformant | Yes | This product meets the material restrictions of Article 4 of the RoHS Directive (2011/65/EU), including Commission Delegated Directive 2015/863. | |
Product Environmental Profile | Yes |
Technical Information
Cable Entry | No in | ||
Number of Outlets | 1 |
Resources
Cutsheet
Installation Instructions
Brochure
Product Environmental Profile
Reviews
Rated 2 out of
5
by
Connor from
Poor quality
Cover/device screws either slide right in or strip out before ever getting tight
Date published: 2022-10-03
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
I need CE certifications - can you please send me an e-mail?
Please reach out to Pass & Seymour Technical Support for further assistance with your request.
Phone: 844-957-3783
Mon - Fri: 8am - 6pm EST (excluding holidays)
tech.support@legrand.us
Best Regards,
Technical Support
Date published: 2023-01-19
Can I mount an S122R from the ceiling to hang a LED disc light form it or a smoke detector on it? The disc light weighs less than a smoke detector.
The UL number is for this box but the rating is for 6 lbs. if mounted vertically. When dealing with inspectors who have little to no common sense every word matters!!
Date published: 2022-06-20
Does the S118W outlet box have a fire rating?
Yes, it is UL Classified for 2 Hour Fire Resistance.
Date published: 2023-01-25
what type of plastic is used in your boxes
Our boxes are made of a durable, impact resistant Thermoplastic material.
Date published: 2021-10-14
what is the distance between boxes in opposing directions in a 1 hr rated wood stud rated wall
Hello Mycitylady,
Thank you for your question, Please review the following response below that is referenced from the attached UL 2hour fire rating document.
UL 2hour Fire Rating: Part S122R
Clearance between boxes and cutouts in ceiling shall not exceed 1/8 in. The area of openings for boxes shall not aggregate more than 31 sq in. Per 100 sq ft of ceiling area with no opening exceeding 8 sq in. No box shall be located within 4.5ft of another box.
Best regards,
Justin
Date published: 2022-06-29
what is the dimension of this box? how deep is it?
The dimension for the S122R box is:
Length 3 3/4"
Width 2 1/4"
Depth 3 3/8"
Date published: 2021-04-21
Can the 18r single gang be mounted in clinging and how much weight can it hold
The S118R is designed for wall vertical mount and if a box is not marked with a specific weight then it has a 6lbs maximum fixture rating.
Date published: 2021-01-07
can these be installed in a 2 hour firewall within 2' of an oppsing outlet
For use in fire resistance floor-ceiling assemblies constructed with wood joists, wood flooring and
gypsum wallboard ceilings with 2 hr or less classification periods. Clearance between boxes and cutouts in ceiling shall not exceed 1/8 in. The area of openings for boxes shall not aggregate more than 31 sq in. per 100 sq ft of ceiling area with no opening exceeding 8 sq in.
No box shall be located within 4.5 ft of another box.
Date published: 2020-11-21
Bazaarvoice SAP Hybris Integration Version 2.8.1