DLM Triple Relay Room Controller, 0-10V, 347V
Bazaarvoice SAP Hybris Integration Version 2.8.1
LMRC-210 Series Digital Room Controllers include one, two or three relay(s) to switch a total of 15 or 20 amps, a highefficiency switching power supply and one 0-10 volt output per relay for control of dimmable loads including electronic ballasts (Advance Mark 7, or equivalent). They are the foundation of a Wattstopper Digital Lighting Management (DLM) system, and allow integration of occupancy sensors, daylighting controls and switches for energy-efficient lighting control.
- 120/277 VAC
- 347 VAC
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Features
- Plenum-rated controllers with line voltage relay(s) and 0-10 volt dimming output(s)
- 120/230/240/277 volt and 347 volt models
- Plug to other components using Cat 5e cables with RJ45 connectors eliminating wiring errors
- Plug n’ Go automatic configuration for maximum energy efficiency
- Store load preset level and 16 scene preset levels for each load
- Support energy saving manual-on, bi-level, tri-level and dimming control strategies
Specifications
Product Line | Wattstopper | ||
UPC Number | 754182928958 | ||
Country Of Origin | China |
Product Width US | 7.0 in | ||
Product Weight US | 2.0 lb | ||
Product Volume US | 244.24 cu in | ||
Product Depth US | 7.93 in | ||
Product Height US | 4.4 in |
Product Environmental Profile | Yes |
Resources
CAD Drawings
BIM Models
Software Downloads
Supporting Document
Customer CAD PDF
Brochure
Product Environmental Profile
White Papers & Tech Bulletins
Cutsheet
Installation Instructions
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
My Load light is blinking and it’s turning the lights on and off what’s the problem because everything was working fine
I would like to know if a LMRC-313 wattstopper is still a good part number or if it has been replaced with a new number.
I have a LMRC-212 controller with the LMW-102 and LMDM-101 switches when dimming one load "lights" it dims the second set at the same time. Custome wants a second dimmer to dim one load at the time.
Can you program these to be auto on auto off?
config. light not blinking on the controller. and wall switch unable to turn light on.
Can you Daisy 2 relay boxes together ?
what is the catalog number for LMRC-211 dimmer switch?
what is the strap with the brass clip used for?