The LMPC-600 wireless low profile Digital PIR Ceiling Mount Occupancy Sensor uses passive infrared (PIR) technology and one of three lenses to detect occupancy in different types of spaces for energy-efficient control of lighting and plug loads. It is a digital sensor, and is part of the wireless Wattstopper Digital Lighting Management (DLM) system.

Footprint 35 ft
  • Send
  • Save as PDF
  • Add to favorites Remove from favorites

Features

  • Passive infrared occupancy sensor with a choice of three 360° lens options for different coverage patterns
  • Dual IPv6 Wireless and Bluetooth® low energy antennas provide robust signal strength and reliable communication
  • Uses IPV6 Wireless to establish network communication with all DLM wireless devices
  • Streamlined low profile design and optional recessed mounting, for architectural appeal
  • Snap-on sensor mask for quick and easy coverage pattern customization
  • Up to 10-year battery life; battery level can be viewed with wireless DLM software
  • Extended height lens option for mounting up to 40’

Specifications

General Info
Product Line Wattstopper
Color White
UPC Number 754182942701
Country Of Origin China
Product Series LMPC-600
Features Adjustable Time Delay, Indicator Lights, Room Controller Required, Sensitivity Adjustment
Installation Location Ceiling
Included Battery
Standard UL, cUL, E101196, UL 2043, RoHS, FCC part 15
Warranty Type 5-Year
Type Sensor
Dimensions
Product Width US 3.7 in
Product Weight US 2.8 lb
Product Volume US 17.8 cu in
Product Depth US 3.7 in
Product Height US 1.3 in
Additional Information
RoHS Compliant Yes This product meets the material restrictions of Article 4 of the RoHS Directive (2011/65/EU), including Commission Delegated Directive 2015/863.
Security   Yes This product is ioXt certified
Technical Information
Operating Temperature Min 32 °F
Compatibility Bluetooth, DLM Wireless (IPv6)
Has Battery Yes
Sensor Coverage Pattern 360 deg
Security Method Data Encryption
Battery Capacity 1500 mAh
Sensor Type Occupancy
Frequency Band 2.4 GHz
Operating Temperature Max 104 °F
Sensor Mounting Height 40 ft
Wireless Range Bluetooth, up to 30 ft, IPv6 6LoWPAN, up to 60 ft
Sensor Technology Passive Infrared (PIR)
Topology Wireless Mesh
Antenna Integrated, Internal
Indoor/Outdoor Indoor
Battery Life 10+ Years
Mounting Type Recessed, Surface, Threaded Rod
On Function Auto On
Battery CR123A 3V
Operating Temperature 0°-40°C, 32°-104°F
Operating Humidity 5-95% RH (Non-Condensing)
Sensing Range 70 ft diameter
Encryption AES 128-bit
Storage Temperature 23° - 140° F, -5° - 60° C

Reviews

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Questions & Answers

Can you confirm the voltage reading that would indicate when the battery needs to be replaced.

Asked by: Steve
Battery levels of wireless devices can be found in either the DLM Config App or the LMCS software.
Answered by: Tier 1 Tech Support
Date published: 2024-08-05

We are unable to get the sensor to work with LMRC-611MCC-A controller

Asked by: kenneth
Your devices need to be paired before proper operation. Follow instructions below. Push-to-Pair in a room with a single LMRC-611 Room Controller NOTE: Once you enter PtP mode on the room controller, a three minute timer begins. If the Config button on any device in the room is pressed, the timer resets and begins the three minute countdown again. If no Config button is pressed within three minutes, the room controller will exit PtP mode. 1. Enter PtP mode on the room controller. Press the Config button three times (within three seconds) until the LED on the room controller flashes green. 2. Enter PtP mode on the LMPC-600. Press the Config button three times. As with the room controller, the LED on the sensor will flash green. 3. Pair the LMPC-600. Press the Config button on the LMPC-600 one more time to pair it to the room controller. The load connected to the room controller will toggle once (if the load is OFF, it will turn ON; if ON, it will turn OFF) to indicate that pairing was successful. Also, the LMPC-600’s blinking LED will turn to solid green as another indicator of a successful pairing. NOTE: If there are any wireless sensors, dimmers, or additional switches in the room, repeat steps 2 and 3 for each of those devices so that all devices are paired together in the same network. For each device, the load will toggle during step 3 and its config LED will turn solid green. 4. Exit PtP mode. From any device, press the Config button 3 times. After a few seconds, the LED on each Room controller, switch or sensor currently in PtP mode will flash white and reboot, leaving the default network and migrating to the new network. Then, the LED on the room controller will flash blue and the pairing process finishes.The default Network ID on all devices will change to a new number, based on the last four digits of the Mac address on the room controller, and now those devices will communicate only with each other and not any devices which have not been paired. NOTE: It is important to exit PtP mode within the three minute time limit mentioned above. If you do not, none of the device pairings will be remembered and you have to start the process over from the beginning.
Answered by: Tier 1 Tech Support
Date published: 2024-10-14
  • y_2024, m_12, d_4, h_6CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_en_US, sid_LMPC-600-5, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_legrand
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 9ms
  • QUESTIONS, PRODUCT