Discontinued - PIR Ceiling Occupancy Sensor, 500 sq ft, 24VDC
CI-200-1
Wattstopper
Bazaarvoice SAP Hybris Integration Version 2.8.1
Replaced by CI-300-1
Wattstopper’s CI-200 Series Passive Infrared (PIR) Ceiling Sensors provide 360° coverage to detect occupancy in the controlled area. These low-profile sensors reliably control lighting in a variety of applications.
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Specifications
General Info
Product Line | Wattstopper | ||
Replaced by Part Number | CI-300-1 | ||
UPC Number | 754182913299 | ||
Country Of Origin | China |
Technical Information
Sensor Type | Occupancy | ||
Sensor Technology | Passive Infrared (PIR) |
Resources
Instruction Sheet
CAD Drawings
57-003-1 - Any 8-Wire Occupancy Sensor "Standard Schematic"
dxf
57-003-1 - Any 8-Wire Occupancy Sensor "Standard Schematic"
pdf
57-003-1 - Any 8-Wire Occupancy Sensor "Standard Schematic"
png
57-003-1 - Any 8-Wire Occupancy Sensor "Standard Schematic"
pdf
57-003-1 - Any 8-Wire Occupancy Sensor "Standard Schematic"
dwg
57-010 - Multiple Occupancy Sensors Using One Power Pack
dxf
57-010 - Multiple Occupancy Sensors Using One Power Pack
png
57-010 - Multiple Occupancy Sensors Using One Power Pack
dwg
57-010 - Multiple Occupancy Sensors Using One Power Pack
pdf
57-039-11 - MB-1 Mounting Information using CI-Series Sensors
png
57-039-11 - MB-1 Mounting Information using CI-Series Sensors
dxf
57-039-11 - MB-1 Mounting Information using CI-Series Sensors
dwg
57-039-2 - CI Series Sensor Installation
dwg
57-039-2 - CI Series Sensor Installation
dxf
57-039-2 - CI Series Sensor Installation
pdf
57-039-2 - CI Series Sensor Installation
png
57-041-1 - 8-Wire Sensor Interfacing With A Thermostat
dxf
57-041-1 - 8-Wire Sensor Interfacing With A Thermostat
dwg
57-041-1 - 8-Wire Sensor Interfacing With A Thermostat
pdf
57-041-1 - 8-Wire Sensor Interfacing With A Thermostat
png
57-303 - CI, DT, UT-305 Standard Schematic
png
57-303 - CI, DT, UT-305 Standard Schematic
pdf
57-303 - CI, DT, UT-305 Standard Schematic
dxf
57-303 - CI, DT, UT-305 Standard Schematic
dwg
60-601-2 - LI/LP Relay Panels Occupancy Sensor Connection
pdf
60-601-2 - LI/LP Relay Panels Occupancy Sensor Connection
dxf
60-601-2 - LI/LP Relay Panels Occupancy Sensor Connection
png
60-601-2 - LI/LP Relay Panels Occupancy Sensor Connection
dwg
CI-200
dwg
CI-200
dxf
CI-200
png
CI-200-1
png
CI-200-1
dwg
CI-200-1
dxf
CI-200-1cp - CI-200-1 Coverage Pattern
png
CI-200-1cp - CI-200-1 Coverage Pattern
dwg
CI-200-1cp - CI-200-1 Coverage Pattern
dxf
CI-200cp - CI-200 Coverage Pattern
dxf
CI-200cp - CI-200 Coverage Pattern
png
CI-200cp - CI-200 Coverage Pattern
dwg
CI-205
png
CI-205
dwg
CI-205
dxf
CI-205-1
png
CI-205-1
dxf
CI-205-1
dwg
View More
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
I have a ci 200 series installed in some massage rooms. They are at max setting of 30 minutes and the lights are coming on halfway through a 1 hour session. Is there a solution for this?
Please reach out to our tech. support team for further assistance with over-riding this sensor.
Legrand Technical Support:
Phone: 1 800-879-8585, Option 3 then Option 1
Mon - Fri: 7am - 7pm CST (excluding holidays)
Date published: 2023-03-07
If I set the dip switch 6 to on/enable override, Does the sensor still do auto off or will the sensor be manual on/manual off?
setting DIP switch #6 to bypass will override all the sensor’s occupancy control functions. Lights can still be manually on/off controlled with a light switch.
Date published: 2023-12-15
Lights cycle on and off , been install for 10 years , just start this issue, power supply BZ-50 or sensor CI-205 problem? Are sensor W-500A and W-1000A obsolete ? if so what Replacement recommend ?
Most likely the power pack is the cause.
W500A DISC REC SUB UT3051
W1000A DISC REC SUB UT3052
Date published: 2022-10-24
I would like to completely disable the sensor. How can I do this?
Place all of the dip switches in the On position except for number 6, it will remain Off. This will place the sensor into Service mode.
Date published: 2021-09-15
Bazaarvoice SAP Hybris Integration Version 2.8.1