Power Pack, 120-277V, 50/60Hz, 24VDC, 225mA
BZ-50
Wattstopper
Bazaarvoice SAP Hybris Integration Version 2.8.1
The BZ-50 Universal Voltage Power Pack provides 24 VDC operating voltage to Wattstopper’s low-voltage occupancy sensors. This device is constructed with environmentally friendly materials and is RoHS-compliant.
Connection Type
Wire Leads
- RJ45
- Wire Leads
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Features
- Self-contained power supply relay system
- Efficient switching power supply providing optimized current output based on number of sensors
- LED indicates status of relay or if there is a low-voltage overcurrent
- The product meets the materials restrictions of RoHS
- Zero crossing circuitry for reliability and increased product life
- UL 2043 plenum rated for cost-effective installation
- 1/2” snap-in nipple attaches to standard electrical enclosures through 1/2” knockouts
Specifications
General Info
Product Line | Wattstopper | ||
UPC Number | 754182922901 | ||
Country Of Origin | China | ||
Application Sector | Commercial | ||
Warranty Type | 5-Year |
Dimensions
Product Width US | 3.0 in | ||
Product Weight US | 0.35 lb | ||
Product Volume US | 28.12 cu in | ||
Product Depth US | 3.75 in | ||
Product Height US | 2.5 in |
Technical Information
Amperage | 20 A | ||
Connection Type | Wired |
Resources
Cutsheet
White Papers & Tech Bulletins
Specifications
Installation Instructions
Case Studies
CAD Drawings
BZ-50 Universal Voltage Power Pack
pdf
BZ-50 Universal Voltage Power Pack
dwg
BZ-50 Universal Voltage Power Pack Multiple Power Sensor
pdf
BZ-50 Universal Voltage Power Pack Multiple Power Sensor
dwg
BZ-50 Universal Voltage Power Pack Multiple Power Sensor & Power Packs
dwg
BZ-50 Universal Voltage Power Pack Multiple Power Sensor & Power Packs
pdf
View More
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
Can I use the BZ-50 to control 12watt Led wall lights? Max 3 fixtures, total 36w 120v
Yes, as long as you do not exceed the 20A load limit.
Date published: 2023-09-11
Is there a minimum load requirement for the BZ-50?
How much sensor can use this power pack
Date published: 2023-04-18
What is the recommended relay for the BZ-50?
Does the power pack needs a switch leg from the switch or can i use Switch leg from light for the sensor to work
Date published: 2022-10-31
What is the maximum wire length for the BZ-50 output using 18 AWG wire?
The following attached image is a Tech Bulletin regarding Voltage Loss. It discusses wires lengths, gauges, and the corresponding voltages losses.
Date published: 2022-05-31
Is there a compatible time clock available that intagrates with the power packs
Wattstopper has a low voltage time switch called a TS-400-24 that's compatible with the low voltage power pack.
Date published: 2022-02-17
How long do these last and when will u need to replace them?
The BZ Power Packs come with a 5 year warranty. Although every environment and situation is different, they are expected to last long after that warranty expires.
Date published: 2022-02-01
What is the temperature rating for the BZ50?
The environment temperature range on the BZ50 is 0°C to 40°C.
Date published: 2020-11-21
Trying to put these in an existing building, can I switch the power pack on and off with a switch in the room? Instead of the switch leg coming off the BZ-50?