$4.38 USD
Always find the switch with ease, even in the dark, with this convenient locator light. A great addition to any adorne switch or dimmer.
Quantity
In Stock
Added to Your Shopping Cart
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?
Specifications
General Info
Color | Clear | ||
UPC Number | 785007022803 | ||
Countries Of Origin | China | ||
Product Line | Pass & Seymour | ||
Standard | CULUS, ETL Listed |
Technical Information
Wattage | 0.175 W | ||
Voltage | 125 V | ||
Battery | Not Required | ||
Compatibility | Residential Wiring | ||
Lens Material | Thermoplastic | ||
Lens Color | Clear | ||
Terminals | Wire Lead | ||
Lamp Type | LED |
Resources
CAD Drawings
Guide Form Specifications
Installation Instructions
Customer CAD PDF
Supporting Document
Rated 5 out of
5
by
Jason from
Perfect Look
Easily installed. Looks just as advertised and gives a nice touch to the decor.
Date published: 2020-12-25
Yesterday I installed a standard paddle switch and installed the locator light - which I tested to be sure it was lighting, and it is not visible through the switch when installed. Is there some way to test the switch light transmission and remedy this?
Please contact Technical Support for assistance with resolving this installation issue:
adorne products
1.800.223.4185 opt 3
Mon - Fri: 8am - 6pm EST
(excluding holidays)
Email Us - tech.support@legrand.us
Date published: 2020-11-21
Installed the locator light on paddle switch 3 way with an softap dimmer, the locator light is not light up neither light is on or off. please advise
You should try contacting customer service directly. They’re very helpful.
Date published: 2020-03-07
Is there a way wire the locator light (single-pole/single switch configuration) so locator light is ON when light is on? I have a closet with switch on outside and light gets left on at times. Seeing locator light on would be a reminder that it is on.
To wire the Locator Light as a Pilot Light(lit when on), you need to connect one of it's leads to the 1pole terminal and one to a separate Neutral wire.
Date published: 2020-04-17
How to hook up 4 way
When installing the Locator Status Light in a 4way Paddle switch, the two leads are connected to either both IN terminals or both OUT terminals....see attached
Date published: 2020-01-07
I notice that when I add a paddle switch and the gang plate along with the AALSL6 | adorne, that the paddle becomes really spongy and you don't hear the click and sometimes not even see the light...how do I make sure the AALSL6 | adorne is seated correctl
The light IS inserted too far. It's not impossible to do as I spent an hour swapping switches thinking one was faulty everytime I put in the locator. In fact the instructions or the locator light are faulty - they don't give the right info or the stick is actually too long. If you push the light-stick all the way in so the "bezel" of the light is touching the back of the switch housing (as you would expect to do) the light somehow touches something in the paddle switch and gets in the way so that the switch loses it's "CLICK" when turned on/off. Once the stick is backed out 1/8" or so the switch-click will come back. Hopefully the instructions for this product or the design will be revised - seems like it wasn't ever tested. PS - It's really really a nice feature, and well worth the couple bucks extra, just needs the kinks worked out.
Date published: 2019-06-01
The locator lights are dim in some of the switches I installed. What am I doing wrong?
The Brightness of the locator light can vary slightly based on the load being controlled. Feel free to contact tech support at 1800 223 4185 Option 1
Date published: 2018-11-19
The locator light in several of my switches doesn't go off all the way when the switch is activated...What causes this and how can I resolve it?
Thank you for your question regarding the installation of the adorne Status Locator Light(Model # AALSL6).
Here is the required wiring for each application:
Single pole - connect leads to HOT & 1POLE
3Way - connect leads to 1POLE & 3WAY
4Way - connect both leads to IN or both leads to OUT
adorne products
1.800.223.4185 opt 3
Mon - Fri: 8am - 8pm EST
(excluding holidays)
Email Us - tech.support@legrand.us
Date published: 2019-08-29
How do I install the locator status light with a 3 way or 4 way paddle switch?
Thank you for your inquiry regarding our adorne locator light. In a 3 way, the indicator light blue wires are going to go in the 1 pole and 3 way terminals. In a 4 way paddle, the blue wires will go into the either both of the in terminals or both of the out terminals. Hope this helps!
Date published: 2020-09-15
You may also like...
Added to Favorites
Go to favorites
Remove from favorites?
AAAL1G4 | Legrand
The Accent Nightlight is a stunning addition to any adorne product. It provides a wash of light below the wall plate, acting as a nightlight or as an accent light.
$20.98
Added to Favorites
Go to favorites
Remove from favorites?
ASWR1532W4 | Legrand
An innovative cross between a traditional toggle and a paddle switch, the adorne Whisper Switch features classic, elegant lines and a fluid motion.
$11.28
Added to Favorites
Go to favorites
Remove from favorites?
ASPU1532W4 | Legrand
The adorne Push Switch allows you to turn lights on and off with a simple push-button motion.
$19.98
Added to Favorites
Go to favorites
Remove from favorites?
ASPD1532W4 | Legrand
The Paddle Switch features a simple up and down motion, allowing you to turns lights on and off with ease.
$5.68