text.skipToContent text.skipToNavigation

adorne® 700W sofTap™ Tru-Universal Dimmer

adorne® 700W sofTap™ Tru-Universal Dimmer is rated 4.4 out of 5 by 25.
  • y_2021, m_10, d_22, h_19
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.19
  • cp_1, bvpage1
  • co_hasreviews, tv_4, tr_21
  • loc_en_US, sid_ADTP703TUM4, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_legrand
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getAggregateRating, 143ms
  • REVIEWS, PRODUCT

$84.87 USD

Turn lights on/off, or dim, with just a soft tap of a finger, thanks to inventive micro-movement technology. Plus, as a Tru-Universal Dimmer, it works with virtually any 120V dimmable bulb or fixture, adjusting to the precise light level you want, without the flicker. Made exclusively for use with screwless Wall Plates from the adorne® Collection, sold separately.
Color Magnesium

Quantity

In Stock

Free Shipping on Orders Over $49 and Free Returns

WHERE TO BUY

Features

  • Installs in 15 minutes or less, fitting into an existing electrical box. No new wiring required for typical installation.
  • Perfect for adding precise light level control -- all it takes is a soft tap to turn on/off or adjust brightness.
  • Works with virtually any 120V dimmable bulb or fixture.
  • Self-calibrates when you select your fixture's lighting type, automatically setting the appropriate minimum voltage to eliminate flicker and poor performance.
  • More color options available to fit any style, including finishes to match current hardware and lighting trends.
  • Complete the look with a stunning, screwless adorne® Wall Plate, not included. Available in a range of contemporary colors and finishes. Coordinate with other designer switches & outlets.

Specifications

General Info
Color Magnesium
UPC Number 785007023176
Country Of Origin China
Product Line Pass & Seymour
Number of Switches 1
Type Dimmer
Warranty Type Limited Lifetime Warranty
Standard cULus,
Technical Information
Wattage 700 W
Number of Poles Single Pole, 3-Way
Number of Gangs 1
Voltage 120 V
Mounting Type Box
Connection Screw Terminals
Load Incandescent/Halogen
Connection Type Internal Pressure Plates

Reviews

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 1500ms
  • REVIEWS, PRODUCT
  • bvseo-msg: Execution timed out, exceeded 1,500ms;

Questions & Answers

Installed this with WAC InvisiLED Pro2 24v (LED-TX24) tape light/ WAC 96 Watt Dimmable Power Supply (EN-24100-RBT2-T). Even after setting to low level trim, the lights flash when dimmed. Is there a minimum load for these dimmers? Other suggestions?

Asked by: Powers
The universal dimmer has a 6W minimum load required and for WAC lighting(ELV), the dimmer should be put into Reverse phase.(see User Adjustments section on attached instruction link) https://legrand.webdamdb.com/directdownload.php?ti=55646800&tok=GcNt2dYl9SpC4XAf0iSV9gRR
Answered by: Legrand Technical Support
Date published: 2021-07-09

Im replacing a lutron 3way with a legrand ADTP703TUG4. The wall has 4 wires. (black, white, red and bare). The switch has sockets for hot, neutral, 3 way and pole? what goes where? the diagram doesnt help

Asked by: Skim
Hello, When installing this Legrand dimmer in a 3-way it has to be installed on the load side and the switch needs to be on the line side. We are not able to identify the wires in the wall just what wires need to be connected on the back of this dimmer. Ground wire goes to green, Neutral wire goes to white, Hot goes to black, 3-way and 1 pole need to be matched up between the dimmer and switch. Please contact us at 844-957-3783 if you have any other questions. Thank you,
Answered by: Jeffrey M.
Date published: 2021-05-24

I'm currently using the adorne® 20A 4-Way Paddle™ Switch ASPD2042G4 pairing with 02 Adorne 3-Way Paddle Switches. Can I replace one of the 3-Way Paddle Switches by 01 adorne® 700W sofTap™ Tru-Universal Dimmer ADTP703TUW4?

Asked by: PlKa
Yes, either one 3way switches can be replaced with the dimmer.
Answered by: Legrand Technical Support
Date published: 2021-04-28

I just completed a complete remodel of my Kitchen. I used all Adorne Legrand devices. I am controling my LED undercounter lighting with a soft tap universal dimmer. My Kicher undercounter lighting is buzzing. did not buzz with conv. dimmer

Asked by: Buddy
The Softap dimmer may need to be adjusted for the under cabinet lights you are controlling. If they are ELV(electronic low voltage), you need to put the dimmer into reverse phase. These steps are included with the dimmer instructions: SP/3Way true universal dimmer phase settings….FORWARD or REVERSE: You need to be in the minimum trim level adjustments to change the dimmer phase. To enter Min Level Trim: Hold Rocker button down for approximately 10s after minimum brightness reached. Bargraph LEDs will turn on to indicate cal mode activated. Releasing button within 5 seconds activates automated Min Level Trim feature as described in Initial Turn-on section below. Continuing to hold button for approximately 5 more seconds causes the +/- LEDs to flash, and initiates manual calibration. (basically hold for approx 15 secs until the +/- start flashing) Forward or Reverse Phase Selection Forward Phase is the default as shipped from factory. During manual Min Level Trim, holding On/Off button for approximately 10s toggles between Forward and Reverse Phase. The LED flash rate during calibration is approximately 1Hz for Reverse Phase, approximately 3Hz for Forward Phase. FORWARD phase – FAST blink REVERSE phase – SLOW blink
Answered by: Legrand Technical Support
Date published: 2021-04-13

I have an ADTP703TUW4 in my bathroom that had been working great, but it has stopped retaining the LDL (last dim level), so whenever I turn the light on with the On/Off pushbutton it turns on on the lowest dimming setting. How can I fix this?

Asked by: soravia
I would try resetting the breaker to the dimmer to force it to recalibrate it's settings. If that does not correct it, contact Technical Support for further assistance. adorne products 1.800.223.4185 opt 3 Mon - Fri: 8am - 6pm EST (excluding holidays) Email Us - tech.support@legrand.us
Answered by: Legrand Technical Support
Date published: 2021-01-03

Will this switch ADTP703TUM4 dim this light? https://www.lumens.com/geos-led-flushmount-by-dweled-uu572078.html I've got your paddle dimmer installed and it flickers. Thanks

Asked by: Byron
Yes, the ADTP703TUM4 is rated to handle ELV loads, where the Paddle dimmer is not. This is from the Lumens spec sheet for your light: Dimmable When Used With a Electronic low voltage (ELV) Dimmer (Not Included)
Answered by: Legrand Technical Support
Date published: 2020-10-06

Does this dimmer REALLY work with standard 110 VAC 6W LED bulbs? I have several of your LED dimmers that will only reduce the brightness of the LED bulbs to about 75% of full brightness - not very much.

Asked by: davchr
The universal dimmer is designed to dim to approximately 3% of your light load but also depends on the low end restrictions of the LED bulb. Some only dim to 10%.
Answered by: Legrand Technical Support
Date published: 2020-06-25

Can you use with ceiling fan light?

Asked by: River74
You should look into AAFN4S16AM4 see https://smhttp-ssl-40934.nexcesscdn.net/pdf/adorne-Install-AAFN4S16A_340966.pdf
Answered by: JoeTex
Date published: 2020-04-21
  • y_2021, m_10, d_21, h_18CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.19
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_37
  • loc_en_US, sid_ADTP703TUM4, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_legrand