The LMPB-100 Digital Power Booster includes a high-efficiency switching power supply to add power to a DLM local network. It can be used with LMFC fixture controllers or any other Wattstopper Digital Lighting Management (DLM) controllers to allow integration of occupancy sensors, daylighting sensors and switches for energy-efficient lighting control. This device does not include a relay for load control.
  • Send
  • Save as PDF
  • Add to favorites Remove from favorites

Features

  • Plenum-rated controller with switching power supply
  • Can add power to any DLM Cat5e local network
  • Supports LMFC fixture integrated controllers
  • Designed to mount inside an LMZC-301 zone controller to increase low voltage power to a DLM local network
  • Plugs to other components using Cat5e cables with RJ45 connectors eliminating wiring errors

Specifications

General Info
Color White
Product Series LMPB
Type Power Supply
Application Sector Commercial
Product Line Wattstopper
Country Of Origin China
Installation Location Ceiling
Warranty Type 5-Year
Standard UL 2043, cUL, FCC part 15, RoHS
UPC Number 754182938933
Dimensions
Product Depth US 2.0 in
Product Height US 4.0 in
Product Volume US 46.5 cu in
Product Width US 3.0 in
Product Weight US 0.4 lb
Technical Information
Current Draw 150 mA
Number of Connections 3
Connector Type RJ45
Indoor/Outdoor Indoor
Input Voltage 120/230/277 VAC
Line Frequency 50 Hz, 60 Hz
Mounting Type 1/2 in Knockout, 4 in J-Box, Zone Controller
Operating Temperature 0°-60°C, 32°-140°F
Operating Temperature Max 140 °F
Operating Temperature Min 32 °F
Operating Humidity 5-95% RH (Non-Condensing)
Storage Temperature 23° - 176° F

Reviews

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Questions & Answers

Does using an LMPB refresh the 1,000' CAT5 limit? For example, using an LMCP, run 1,000' max to high bay sensors, installing an LMPB and running another 1,000' max.

Asked by: Dan
Hello Dan, The LMPB-100s purpose is to add unswitched 150mA @24vdc to the IRb, a single IRb is 1000' max
Answered by: Tier 1 Tech Support
Date published: 2023-08-23
  • y_2025, m_1, d_25, h_6CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_US, sid_LMPB-100, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_legrand
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 39ms
  • QUESTIONS, PRODUCT